Installation - Graco Pail Mount Packages Instructions And Parts List

Aluminum and stainless steel, 1:1 ratio triton 308 spray packages
Table of Contents

Advertisement

CAUTION
Use a stainless steel package to spray waterborne,
acid-catalyzed, or 2-component materials. Use of
aluminum packages with these materials is not rec-
ommended. See the wetted parts in the Technical
Data section of each component manual, and your
fluid and solvent manufacturer's compatibility infor-
mation.
WARNING
TOXIC FLUID HAZARD
Hazardous fluid or toxic fumes can
cause serious injury or death if splashed
in the eyes or on the skin, inhaled, or
swallowed.
D Read TOXIC FLUID HAZARD on page 5.
D Use fluids and solvents that are compatible with
the equipment wetted parts. Refer to the Tech-
nical Data section of all equipment manuals.
Read the fluid and solvent manufacturer's
warnings.
General Information
D Always use Genuine Graco Parts and Accessories,
available from your Graco distributor. If you supply
your own accessories, be sure they are adequately
sized and pressure rated for your system.
D Reference numbers and letters in parentheses refer
to the callouts in the Figs. and the parts lists start-
ing on page 12.

Installation

Preparing the Site
D Ensure that you have an adequate compressed air
supply for the pump and gun. Refer to the separate
pump and gun manuals for air consumption data.
D Clear obstacles and debris that could cause an
unsafe operating environment.
D Have a grounded, metal pail available for use when
flushing the spray package.
D Bring an air supply line (C) from the main air supply
to the pump location. Install an accessory air filter
(D) on the compressed air line to filter dirt and
moisture from the air supply. Install a shutoff valve
(E) to isolate the filter for cleaning.
D When the bleed-type master air valve (B) is closed
and the pump air regulator (F) and gun air regulator
(G) are opened, it relieves all air pressure to the
system components.
D Ventilate the spray booth.
To prevent hazardous concentrations of toxic
and/or flammable vapors, spray only in a properly
ventilated spray booth. Never operate the spray
gun unless ventilation fans are operating.
Check and follow all of the national, state, and local
codes regarding air exhaust velocity requirements.
WARNING
309304
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents