Troubleshooting A Wet System - Dell PowerEdge R730 Owner's Manual

Rack servers
Hide thumbs Also See for PowerEdge R730:
Table of Contents

Advertisement

7.
Ensure that all network cables are of the proper type and do not exceed the maximum length.
Next steps
If all troubleshooting fails, see

Troubleshooting a wet system

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
Steps
1.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2.
Remove the system cover.
3.
Remove the following components from the system:
hard drives
hard-drive backplane
USB memory key
hard-drive tray
cooling shroud
expansion-card risers (if present)
expansion cards
power supply unit(s)
cooling-fan assembly (if present)
cooling fans
processor(s) and heat sink(s)
memory modules
4.
Let the system dry thoroughly for at least 24 hours.
5.
Reinstall the components you removed in step 3.
6.
Install the system cover.
7.
Turn on the system and attached peripherals.
If the system does not start properly, see
8.
If the system starts properly, shut down the system, and reinstall all the expansion cards that you
removed.
9.
Run the appropriate diagnostic test. For more information, see
Next steps
If the tests fail, see
Getting
Getting
Help.
Getting
Help.
Help.
Using System
Diagnostics.
183