Error message
NO FORMFEED RECEIVED
ERROR LCA !!
CALL SERVICE
CHECKSUM ERROR !!
MAKE DEFAULT RESET
CHECKSUM ERROR !!
MAKE COUNTER RESET
TEST MACRO TOO LONG
BUFFER OVERFLOW !!
PROM ERROR !!
PROM ERROR !!

Note on maintenance:

\text\da590\errormes
VERIFY U9
VERIFY U43
Make sure that the feed rollers are always kept clean.
Cause
No form feed character (0C
hex) was received after an
address was sent.
Error in loading the LCA
module.
Error in buffered RAM
Error in the buffered RAM for
ink status counter.
User-defined test address is
too long.
Error in data transfer
Incorrect or missing Eprom
U9.
Incorrect or missing Eprom
U43.
8.2
Error messages and solutions
Solution
Check the program setup in
your software.
Call for service !
Switch the printer off.
Perform a default reset.
Sec. 5).
With this error message you
may continue to use the printer.
Reset the ink status counter
with the "HEAD RESET" menu
in programming mode.
(see Sec. 5).
Limit the size of the test
address to 3 Kbytes.
If you are working in block
rotation (= "Rev" in the
display), the test address may
not exceed 8 lines.
Check the connection of the
interface cable.
Check the corresponding
Eprom U9.
Check the corresponding
Eprom U43.