Ipi/Standing Pilot System Information - Mendota DT3-PF2-LX Operating Instructions Manual

Gas direct vent fireplace with premium fiber log set combustion system
Table of Contents

Advertisement

IPI/STANDING PILOT SYSTEM INFORMATION

Supply voltage
Ambient temperature ratings
Radio Frequency
·
The transmitter and receiver are RADIO FREQUENCY DEVICES.
·
Turn off the main gas supply of the appliance during installation or maintenance of the receiver.
·
Toggle the Master Switch to OFF during installation or maintenance.
·
During appliance installation/maintenance or in case of remote control malfunction, turn off electrical sup-
ply to this appliance and remove the Backup batteries. Contact technical service.
Intermittent Pilot Light and Standing Pilot Light Features
This gas fireplace is equipped with an electronic ignition System that first lights a pilot light then uses the pilot light to ignite
the main burners. The pilot light can be set in the CPI (Standing Pilot) mode to allow the pilot light to remain on indefinitely
by setting the Remote Transmitter to CPI mode. If the remote transmitter is set to the IPI (Intermittent Pilot) mode, the
pilot light will only light and remain ON while the main fireplace burners are operating.
IPI Mode: This mode turns the pilot light "OFF" when the fireplace is not functioning and only lights the pilot light automat-
ically when a call for heat is made by the remote control.
(CPI) Standing Pilot Mode: If set to CPI Mode, the
pilot light will ignite and remain ON at all times.
Setting to IPI versus CPI mode:
With the remote transmitter OFF, press the MODE
button. You will see either "CPI" or "IPI" displayed
on the transmitter screen. Press the UP arrow but-
ton to set "CPI" mode and press the DOWN arrow
button to set "IPI" mode. One set to the desired
setting, press On/Off button to activate the fire-
place.
NOTE: Mendota Fireplaces recommends that
the (CPI) Standing Pilot Mode be used during the winter months when the average daily high temperature falls
o
below 50
F. This will keep the fireplace chimney heated for proper updraft during burner ignition and it will also eliminate
excessive condensation of exhaust vapors on the door glass. Further, leaving the fireplace in the Standing Pilot Mode will
keep the fireplace body warm and eliminate cold drafts and heat loss to the cold air that is trapped inside the firebox.
38
REMOTE CONTROL
4.5V (three 1.5V AAA batteries)
32 – 122
315 MHz
ATTENTION!
o
o
F (0 – 50
C)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv-45 dt4 - lx

Table of Contents