Initializing The Remote Control System - Mendota DT3-PF2-LX Operating Instructions Manual

Gas direct vent fireplace with premium fiber log set combustion system
Table of Contents

Advertisement

"FIRST TIME" PILOT LIGHTING INSTRUCTIONS
IMPORTANT: Be sure all items on "INSTALLATION CHECK OFF LIST" in the Installation Manual have been completed!
CAUTION: If the pilot goes out, be sure to wait a minimum of five minutes before attempting to relight the pilot.
1. Make certain that any manual gas supply shut-off valves located upstream of
fireplace are open and the Master On/Off switch is toggled to the ON position.
2. Make certain that 110VAC power is connected to Electrical Junction Box on left
side of Fireplace and that the Electrical Power is "ON".
3. Insert Batteries in the Remote Transmitter. Note the polarity of batteries and
insert as indicated on the battery compartment cover.
4. For the "First Time Lighting", Remove the Glass Door. This is required to purge
the gas line of air and to inspect the pilot lighting spark.
5. Press OFF on the remote Transmitter. Press MODE button on Transmitter.
Press UP for "CPI" (standing pilot mode). Press MODE button again to exit.
You will hear a series of clicks and after a few seconds, you will hear sparking
at the pilot spark electrode.
6. Allow adequate time for the air in the gas-line to purge. The control system will stop sparking after 30 seconds if the
pilot light does not light. After a 30 second delay the control system will start sparking again for 30 seconds more. If
the pilot light does not light after the third 30 second spark event, the system will enter "Lock-out" mode. To unlock
from "Lock-out" mode, Press the ON/OFF button on Transmitter then Press ON/OFF button on the transmitter again
so the Transmitter display turns off. Wait 30 seconds. Turn OFF the Master Switch. Wait 30 seconds and Turn Master
Switch ON again. Repeat this sequence until the pilot flame lights and the pilot is burning steadily.
7. Once the pilot flame is lit and well-established, close glass door. WARNING: NEVER IGNITE MAIN BURNERS WITH
GLASS DOOR REMOVED OR OPEN. Doing so will lead to damage to pilot flame sensor and spark electrode
wire leads.
8. Press the ON/OFF button on Transmitter to "ON". All burners should ignite
and run at "high-fire". Toggle through other functions of the Fireplace
(Flame Height, Fan Speed and Accent Light brightness) to verify all func-
tions.
9. Perform gas inlet and outlet pressure tests and leak tests on field installed
gas fittings and factory installed fittings in the gas valve compartment, at this
time. Note: Burners must be ON to check outlet pressures and to leak test
gas train fittings upstream of main gas valve.

INITIALIZING THE REMOTE CONTROL SYSTEM

MASTER SWITCH: Remote Transmitter WILL NOT communicate to receiver
unless the Master Switch is ON. The master switch when OFF disable all
functions and acts as a Master Safety Shutoff Switch.
(Synchronizing Receiver and Transmitter)
Master Switch and Sync Switch are located beneath the Glass Frame.
1. Toggle Master Switch to ON (pull toward front of unit). Remote Transmitter
WI LL NOT communicate to receiver unless the Master Switch is ON.
2. Locate Sync Switch (directly above Master Switch). Press the Sync Button.
The receiver will beep 3 times indicating that it is ready to synchronize with
a Remote Transmitter.
3. Push the "ON" key on the Remote Transmitter. The receiver will beep 4
times to indicate that the Transmitter's command is accepted and sets to
the particular code of that Transmitter. The system is now initialized.
NOTE: Once synchronized, the Transmitter and Receivers will communicate
permanently and no further Synchronizing steps are necessary unless either
the Transmitter or Receiver is replaced.
37
REMOTE TRANSMITTER
BLUE LCD
DISPLAY
ON/OFF KEY
THERMOSTAT
SELECTION KEY
UP/DOWN
SELECTION KEY
MODE
SELECTION KEY

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxv-45 dt4 - lx

Table of Contents