FC-Series S Camera Installation
1.4.3
Camera Mounting for Rear Cable Access
The FC-Series S camera can be secured to the mount with two in-line 1/4-20 threaded fasteners on
the top or bottom of the camera. Alternatively the camera can be mounted with four M5 x 0.8 threaded
fasteners to the bottom of the camera. Use Loctite 222 low strength threadlocker for the top mount
fasteners (can be used with the bottom mount fasteners also). Refer to the FC-Series S ICD, FLIR
Doc. # 427-00XX-XX-19S for additional information.
If using two 1/4-20 fasteners in the center of base, the maximum depth of the fastener should not
exceed 12.5 mm (0.5 in). If using four M5 x 0.8 fasteners, the maximum depth of the fastener should
not exceed 10.0 mm (0.4 in).
Figure 1-1: FC-Series S Camera Bottom Mounting Holes
Figure 1-2: Top Side Mounting Holes
If using two 1/4-20 fasteners in the center of top, the maximum depth of the fastener should not
exceed 12.5 mm (0.5 in). If the camera is mounted using the top of the camera, the sunshield must be
removed.
427-0073-11-12, version 100
January 2013