1
FC-Series S Camera Installation
To ensure a water tight seal when using the supplied rear cable gland, cable dimensions must be
within the minimum and maximum as described in Table 1-3.
Power (3 conductor),
Ethernet, Accessory
cables
RG 59 Video cable
If non-standard cable diameters are used, an appropriate cable gland and insert should be used to fit
the desired cable and to fit the hole in the enclosure. FLIR Systems, Inc. does not provide cable gland
inserts other than the insert supplied with the system.
If a replacement is used, inspect and install the gland fitting in the back cover with suitable leak seal or
sealant and tighten to ensure water tight fittings. To fit the 1.050 in. (26.7 mm) hole in the enclosure,
the thread size should be 3/4" NPT or M25. The gland should be installed with a sealing washer (for
example, Heyco PN 3261 or equivalent) between the gland and the external surface of the enclosure.
427-0073-11-12, version 100
Accessory cable
(not used, fill with plug)
Ethernet
Table 1-3: Rear Exit Cable Min/Max Dimensions
Cable
Minimum
4.5 mm
[0.178 in]
5.3 mm
[0.209 in]
Figure 1-12: Cable Routing
Maximum
When using the concealed cable wall mount
5.2 mm 
(PN 4129742), cables can have a maximum diameter
[0.205 in]
of 10 mm [0.394 in]
6.4 mm 
[0.245 in]
January 2013