Triggers

A REMOTE TRIGGER IN port allows all channels to turn on or mute simultaneously. The REMOTE TRIGGER
INPUT can receive 5-24 Volts AC or DC. The 12 Volt DC REMOTE TRIGGER OUT can be used to turn on other
equipment, additional A6s or other amplifiers, or to perform automated functions desired by the user. Use
3.5mm mono interconnect cables to make Trigger connections.

SYSTEM TRIGGER IN

To mute/un-mute all channels simultaneously, connect a system-wide 5-24 Volt DC triggering source to the
SYSTEM TRIGGER IN port using a 3.5mm mono interconnect cable. Examples of triggering sources include an
ELAN Multi-Zone Controller's SYSTEM TRIGGER OUT or REMOTE OUT, an A/V receiver's switched outlet con-
nected to a power supply, or a +12VDC TRIGGER OUT from another ELAN amplifier.
3.5mm mono
interconnect
cable
S66A
A6
Figure 3-4: Remote Trigger In

SYSTEM TRIGGER OUT

Whenever the A6 is powered ON, the REMOTE TRIGGER OUT becomes active. This output sends a +12VDC
100mA signal to other devices with a Trigger Input. Examples of proper usage of the REMOTE TRIGGER OUT
include muting/un-muting other amplifiers, triggering the switched outlets of a Z•Power Controller, or triggering
®
automated events using ELAN
Sense Sensors and VIA! SR-1 or SS1 devices.
From S66A
To A6
#3-4
3.5mm mono
interconnect
cable
A6 #1
A6 #2
Figure 3-5: Remote Trigger Out
Page 16