Installation; Installing Freestanding Dispensers - Follett Symphony 25CT400A Installation, Operation And Service Manual

Symphony 25 / symphony 50 series ice and water dispensers
Table of Contents

Advertisement

Installation procedure
Before you begin
• All dispensers must be installed level in both directions to ensure proper operation
• Required ventilation and recommended service clearances:
• Countertop and wall mount models with Satellite-fi ll icemaker (25CR400A/W, 25HR400A/W, 50CR400A/W, 50HR400A/W)
— none. 12" (305mm) at top recommended for service
• Countertop and wall mount models with integral icemaker (25CT400A/W, 25HT400A/W, 50CT400A/W, 50HT400A/W) —
6" (153mm) at top. 6" (153mm) each side recommended for service
• Freestanding models (25FB400A/W, 50FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top recommended for service
• All countertop dispensers provide the option of taking utilities out the bottom or back of the dispenser.
See counter cut-out on page 9 (Fig. 2) for bottom exiting utilities on units with and without drain pans. For installations where
utilities will exit through back of dispenser, refer to back view drawings.
• Wall mount models are designed for use above sinks or custom drain pans, and are not normally equipped with
integral drain pans. Front of sink should be a minimum of 23" (584mm) from back wall. Connection of utilities through the
back for wall mount units is the same as shown in drawings for countertop models except that the drain pan is absent.
• SensorSAFE dispensers are shipped with a plastic, protective fi lm on sensor lenses. For proper operation, plastic
fi lm must be removed after installation.

Installing freestanding dispensers

1.
Carefully tip dispenser back to expose underside and block up in place.
Do not tilt unit further than 30° off vertical.
!
2. Remove legs from shipping box (taped to drain pan of dispenser) and screw into dispenser bottom, taking care to
seat legs securely against underside of dispenser.
3. Position dispenser in desired location and adjust legs to level in both directions.
4. Connect water supply to 3/8" FPT fi tting on back of dispenser (Fig. 1A).
5. Remove 3/4" dispenser drain line plug from back of unit and discard. Connect separate drain lines to 3/4" FPT
dispenser drain fi tting (Fig.1B), and 3/4" MPT icemaker drain fi tting (Fig. 1C) on back of dispenser.
6. Run drain lines to wall or fl oor drain. Provide an air break between the drain lines and drain. If icemaker drain fi tting
is below an intended wall drain, a condensate pump must be used.
7. If icemaker is a water-cooled unit, connect water-cooled condenser supply line to 3/8" FPT condenser inlet fi tting on
back of dispenser (Fig.1D).
Note: Do not run condenser supply water through icemaker water fi lter system.
8. Connect condenser drain line to 3/8" FPT condenser outlet fi tting on back of dispenser (Fig.1E).
Important: Do not connect condenser drain line to any other drain lines.
9. Plug dispenser into 20 amp rated NEMA 5-20 wall socket.
10. Remove front cover of base section by removing two screws at bottom corners of cover. Allow cover to drop
approximately 3/8" (5mm) and pull forward.
11. Turn on water supply and check that water level in fl oat reservoir (when full) is within 1/4" (6mm) of mark on side of
reservoir, and that fl oat moves freely. Check for leaks.
7