8
SET MODE
D Auto power save function "PS"
The auto power save function reduces current drain by deac-
tivating the receiver circuit for preset intervals.
• OFF : The power save function is turned OFF.
• ON : The power save function is turned ON. The power
save function will be activated when no signal is re-
ceived, and no operation is performed for 5 sec.
Auto power save ON
(default)
20
PUSH
Auto power save OFF
D Self check function "SC"
The self check function checks transceiver conditions by it-
self, and informs you in case a problem is found. The follow-
ing items are checked after the power is turned ON, then it
switches to operation mode.
• Temperature : Outside of –35°C to +73°C (approx.)
• Connected battery voltage
• Water intrusion
PUSH
Self check OFF (default)
When error messages as shown below are displayed, see
trouble shooting for advice (p. 27).
Temperature error
Battery voltage error
Self check ON
Water intrusion error