Optional Left-Hand Wiring; Plumbing-Water Connections - Raypak 259 Installation & Operating Instructions Manual

84 professional gas-fired pool & spa heater
Table of Contents

Advertisement

OPTIONAL LEFT-HAND WIRING

If the standard right-hand electrical wiring is not acces-
sible or convenient, wiring can be done from the left-
hand side instead. Conversion is done using the fol-
lowing method:
1. Locate the plug on the left-hand side of the unit.
2. Remove plug and set aside.
3. Locate the junction box. Remove the screw hold-
ing the cover in place and set the cover aside.
4. Pull the bundle of heater wires back in from the
right jacket panel.
5. Remove the grommet from right panel and replace
with the plug from the left-hand side.
6. Route supply lines from the left side and through
the provided loops under the control panel (see
image).
7. See provided wiring tag for correct connection
points.
8. Reinstall the junction box cover when completed.
PLUMBING—WATER CONNECTIONS
The heater has standard right-hand plumbing connections, but can be converted to alternate configurations as
shown below.
STANDARD RIGHT-HAND CONNECTIONS
PRV
LEFT-IN / RIGHT-OUT CONNECTIONS
PRV
IN
PULL WIRES THROUGH
LEFT SIDE PANEL
ROUTE SUPPLY
LINES THROUGH
PROVIDED LOOPS
FLOW
SWITCH
FLOW
SWITCH
OUT
OUT
IN
IN
FLOW
SWITCH
FLOW
SWITCH
OUT
OUT
28
Optional left-hand wiring
LEFT-HAND CONNECTIONS
RIGHT-IN / LEFT-OUT CONNECTIONS
PLUG RIGHT
SIDE PANEL
PRV
PRV
IN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

40984 professional

Table of Contents