NOTE: The LCD temperature display may not agree with the temperature reading of your pool or spa ther-
mometer. The heater reads the water temperature at the inlet. Due to the circulation characteristics of any pool
or spa, the water temperature at the inlet to the heater may differ from that observed at a given location in the
pool or spa.

STATUS AND DIAGNOSTICS

The digital thermostat models are programmed to display a variety of status and diagnostic messages, depend-
ing on the operating conditions.
The following heat status messages are displayed in
Pool, Spa, and Remote modes when there are no
active fault conditions.
Display
Call for heat established, flame pres-
Heating
ent
Spark
Spark operating
No
Heat demand is satisfied or the unit is
Demand
in its 30 second post-purge timeout
Blower is powered for a 45 second
Pre Purge
purge prior to trial for ignition.
The following conditions are displayed in Pool, Spa
and Remote modes.
Display
Sensor
Thermistor temperatures disagree
Failure
by more than 2°F
Thermistor sensor failed open.
Sensor Open
(Below -25°F)
Thermistor sensor failed short.
Sensor Short
(Above 213°F)
Board is sensing flame when both
Flame w/o
main and pilot valves are command-
CFH
ed shut.
MV Output
Main gas valve output is not in com-
Fault
manded state.
Internal Fault Board fault, replace board.
Memory fault. Cycle power and
EEPROM
reset set points. Replace board if
Fault
fault does not clear.
Clock/
Time clock/fireman switch circuit is
Fireman Sw
open.
Low Temp
Water temperature below 36°F.
Lockout
Condition
Condition
The following conditions are displayed only while there
is a demand for heat present.
Display
Water Sw
Water flow switch open.
Open
Blocked Vent Blocked switch is open.
Hi Limit 1
High limit 1 open.
Fault
Hi Limit 2
High limit 2 open.
Fault
Vent Temp
Unused spare circuit is open.
Limit
Air Flow Sw
Air pressure switch not closed with-
Open
in 10 seconds of blower activation.
Air Flow Sw
Air pressure switch is closed prior to
Closed
the blower being turned on.
3 fan switch faults within same heat
Fan Lockout
demand cycle, power must be
cycled to clear the fault.
Ignition
Alternating with "Ign Failure" -
Lockout
Failure to ignite and sense flame in
(Propane Tab
4 second trial for ignition with
Broken)
Propane "15" or "90" tab broken.
Ign 60min
After 3 failed ignition attempts, the
Delay
heater will lock out for 60 minutes
(Propane Tab
before retrying.
Not Broken)
End of Line Test. Mode button stuck
EOL
in closed position.
37