4. ELECTRICAL WIRING

Wiring

Electrical installation should be done by a licensed
electrician only.
1. Confirm the power supply is at the rated voltage of
the appliance and make the connection.
2. Ground the heater.
3. Wiring must be installed by a professional installation
technician and follow the circuit diagram.

Electrical Connections

Electrical installation should be done by a licensed
electrician only.
Refer to the unit rating plate below the control panel for
precise power requirements for your unit, and for ampacity
and over-current protection requirements.
All wiring must be in accordance with the National Electrical
Code, NFPA No. 70, latest edition, and all applicable state
and local codes. The wiring diagrams are located on page
13 through page 16.
WARNING: This heater MUST be installed using
A
flexible conduit for supply wiring to the unit. This will
allow movement of the conduit whenever the junction
box is removed for service.
Locate the equipment disconnect means within 3 ft.
(0.9 m) of the heater's electrical enclosure, or as close to
the heater as possible. Always satisfy applicable codes
and standards.
In sizing power wiring, be especially aware of up-sizing
requirements necessary due to wiring distances. Always
satisfy applicable codes and standards.
NOTE: Refer to the National Electrical Code, Article
680, for general requirements for swimming pools and
equipment, and to Article 440 for special considerations
necessary for circuits supplying hermetic refrigeration
motor/compressors.
This heater is pre-wired to work with external control
systems, heat-on-demand options and other external time
clock overrides. Refer to the external control system's
instructions.
12
Models
Power
CROSSWIND-30-I
CROSSWIND-40-I
CROSSWIND-50-I
208-230VAC
60HZ/1PH
CROSSWIND-65-I
CROSSWIND-40-O
CROSSWIND-50-O
CROSSWIND-65-O
* Reference only - see National Electric Code or local codes for wire gauge length
limits.
Table D.
Electrical Power Requirements
Automation Control,
Inverter Models Only
2-Wire System - Heat Only
The Crosswind inverter models have temperatures sensor
for temperature automation control.
Heater 2-Wire Controllers (Heat Only)
1. Install wires from the automation controller for "Heat"
on the terminal strip inside the heater electrical
compartment on the side of the heater.
2. Remove the jumper wire on the terminal block from
terminals marked #5 and #6. See Figure 11, and
wiring diagrams on page 15 and page 16.
L
5 6
CUSTOMER REMOTE
CONTROL SWITCH
CONNECTOR
208 -230V/60HZ
Figure 11. Automation Control 2-Wire System Connection
3. Install the automation control wires for "Heat" to
terminals #5 and #6.
4. Set temperature setting on the heater to 104°F
(40°C).
NOTE:
When
the
automation
HEAT command the unit will be in the HEAT mode.
When the automation controller does not have a HEAT
command the unit will be in the OFF mode.
Breaker Size
Min.
(Amp)
Circuit
Ampacity
min.
max.
12A
15A
15A
16A
20A
20A
17.2A
20A
25A
12A
15A
15A
12A
15A
15A
16A
20A
20A
20A
20A
25A
YLW/GRN
L
P
P
1
2
1
2
POWER
PUMP CONTROL
controller
has
a

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents