PRODUCT DATA SHEETS
Base Grille Water Filtration
System Model WF-NLC250/NLC250
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANS/NSF Standard 53 for the reduct on of Lead, Cysts andTurb d ty.
Capacity; 250 Gallons (946 Liters)
Service Flow Rate: 0.5 GPM (t,89 L/min,) @60 psi.
Substance
Reduction
U.S. EPA
Average
Maximum
Average
Minimum %
Average
% NSF Test
Aesthetic
Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
N/A
1.9 mg/L
N/A
0.04 mg/L
N/A
97.9%
994707
Particulate
N/A
610,000/mL*
N/A
154/mL
N/A
99.97%
994711
Contaminant
U.S. EPA
Average
Maximum
Average
Minimum %
Average
% NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Cyst
99.95%**
89,250/mL*
6/mL
2.3/mL
99.993%
99.997%
994710
Turbidity
0.5 NTU
29 NTU
0.1 NTU
0.09 NTU
99.5%
99.69%
994710
Lead: @pH 6.5
0.015 mg/L
0.16 mg/L***
0.001 mg/L
0.001 mg/L
99.4%
99.4%
994708
Lead: @pH 8.5
0.015 mg/L
0.16 mg/L***
0.002 mg/L
0.001 mg/L
98.8%
99.4%
994709
Base Grille Water Filtration
System Model WF-LC400/LC400
Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine (Class I) Taste and Odor and against
ANS/NSF Standard 53 for the reduct on of Lead, Cysts andTurb d ty.
Capacity; 400 Gallons (15t4 Liters)
Service Flow Rate: 0.5 GPM (t,89 L/min,) @60 psi.
Substance
Reduction
U.S. EPA
Average
Maximum
Average
Minimum %
Average
% NSF Test
Aesthetic
Effects
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Chlorine Taste/Odor
N/A
2.0 mg/L
N/A
0.04 mg/L
N/A
98%
994707
Particulate
N/A
610,000/mL*
N/A
154/mL
N/A
99%
994711
Contaminant
U.S. EPA
Average
Maximum
Average
Minimum %
Average
% NSF Test
Reduction
MCL
Influent
Effluent
Effluent
Reduction
Reduction
Number
Cyst
99.95%**
89,250/mL*
6/mL
2.3/mL
99.993%
99.997%
994710
Turbidity
0.5 NTU
29 NTU
0.12 NTU
0.09 NTU
99.59%
99.69%
994710
Lead: @pH 6.5
0.015 mg/L
0.16 mg/L***
0.001 mg/L
0.001 mg/L
99.4%
99.4%
994708
Lead: @pH 8.5
0.015 mg/L
0.16 mg/L***
0.002 mg/L
0.001 mg/L
98.8%
99.4%
994709
It is essential that operational, maintenance, and filter
replacement
requirements be carried out for the product to
perform as advertised.
Model WF-NLC250
Change cartridge at least every 6-9
months. Use replacement cartridge NLC 250, part# 9902.
2000 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Model WF-LC40O The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended
that you
replace the filter. Use replacement cartridge LC400, part#
9902. 2000 suggested retail price of $39.95 U.S.A./S49.95
Canada.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the "Assistance or Service" section for the
Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application
GuidelinesP_/ater
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
*Test requirement is at least 1OO,OOO particles/ml
of AC Fine Test Dust. **Cyst performance
is % reduction based on NSF Standard 53. ***Test
requirement is O.15 mg/L ± 10%. These contaminants
are not necessarily in your water supply. Performance may vary based on local water conditions.