Lynx C AD 3320 D Reference Manual

3000 series minimodules dual analog audio to aes converter

Advertisement

Quick Links

Reference Manual

C AD 3320 D / C AD 3321 D
Dual Analog Audio to AES Converter
C AD 3320 D
VID REF
made in Germany
www.lynx-technik.com
AES
AUDIO IN
© LYNX Technik AG
Brunnenweg 3
64331 Weiterstadt
Germany
www.lynx-technik.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C AD 3320 D and is the answer not in the manual?

Questions and answers

Summary of Contents for Lynx C AD 3320 D

  • Page 1: Reference Manual

    Reference Manual C AD 3320 D / C AD 3321 D Dual Analog Audio to AES Converter C AD 3320 D VID REF made in Germany www.lynx-technik.com AUDIO IN © LYNX Technik AG Brunnenweg 3 64331 Weiterstadt Germany www.lynx-technik.com...
  • Page 2 Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Information in this document is subject to change without notice. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical for any purpose, without express written permission of LYNX Technik AG.
  • Page 3: Warranty

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Warranty LYNX Technik AG warrants that the product will be free from defects in materials and workmanship for a period of two (2) years from the date of shipment. If this product proves defective...
  • Page 4: Regulatory Information

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Regulatory information Europe Declaration of Conformity LYNX Technik AG Brunnenweg 3 D-64331 Weiterstadt Germany Declare under our sole responsibility that the product TYPE: C AD 3320 D / C AD 3321 D...
  • Page 5: Table Of Contents

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Contents Warranty ....................3 Regulatory information................4 Europe....................4 Declaration of Conformity .............4 USA....................4 FCC 47 Part 15 ................4 Contents ....................5 Getting Started ..................7 Packaging ..................7 Product Description ................7 Features ....................8 Functional Diagram ................9...
  • Page 6 Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 This page is intentionally left blank Page 6...
  • Page 7: Getting Started

    LYNX control software. The C AD 3320 D / C AD 3321 D is part of the 3000 series of MiniModules, which offer high quality, modularity and flexibility in a very small form factor ideal for applications where space is at a premium.
  • Page 8: Features

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 tightly integrated space saving system where up to 10 MiniModules can be mounted utilizing the optional LYNX R FR 3005 / 3010 rack housing. This includes integrated power supply and optional remote control interfaces.
  • Page 9: Functional Diagram

    Remote Status Alarm Switches Figure 1- C AD 3320 D / C AD 3321 D Functional Diagram Module Layout Figure 2 shows the physical layout of the C AD 3320 D / C AD 3321 D MiniModule. This module utilizes two SubD connectors for the audio input and outputs and AES reference.
  • Page 10 Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Alarm LED Front Side C AD 3320 D VID REF made in Germany www.lynx-technik.com AUDIO Power / Data Connection Bottom DIP Switch 1 1 2 3 4...
  • Page 11: Connections

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Connections Audio Connections The C AD 3320 D / C AD 3321 D MiniModule is configured for SubD audio connections for audio I/O and a BNC connector for video reference. The SubD connectors should be wired in accordance with the tables below.
  • Page 12: Audio Output Connector (Balanced)

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Audio Output Connector (balanced) SubD 15-pin female connector Connection Connection Number Number + AES Ref in - AES Ref in GND AES Ref in + AES OUT 2...
  • Page 13: Power Connections

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Power Connections If using the module in a stand-alone application use the separate R PS 3001 E (for Europe) or R PS 3001 U (USA) power brick option or the R PS 3003-3...
  • Page 14: Installation

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Installation Mechanical Stand Alone Operation The C AD 3320 D / C AD 3321 D MiniModule can be used in a stand alone application. There are two options for the use of the module in this way.
  • Page 15: Multiple Units

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Multiple Units Most applications will require more than one MiniModule, which can include any of the available Series 3000 MiniModule product range. There are two options for mounting multiple units.
  • Page 16: Electrical Installation

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Electrical Installation. Stand Alone Operation The MiniModule requires the R PS 3001 power brick option for stand-alone operation. Two versions are available R PS 3001 E for European markets and R PS 3001 U for the US markets or the R PS 3003-3 desk power supply.
  • Page 17: Multiple Units

    Settings and Control The C AD 3320 D / C AD 3321 D has an integrated micro-controller, which enables the module to be configured and controlled locally via the integral...
  • Page 18: Switch Settings

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Switch Settings Below the switch settings for the 8-position dip- switch are defined. Please refer to figure 2 for the location of the switch. DIP Switch 1...
  • Page 19: Switch Function Detail

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 * Value selected depends on the range selected with switch 5 ** Value selected depends on range selected on switch 2 Switch Function Detail Dip Switch 1: Switch 1. Local Control Enable. ON enables local control (LED 3 green) and makes selections on the DIP switches active.
  • Page 20: Auto Store

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Switch 2. Select full scale range (Switch 1 OFF) ON =15dBu for C AD 3320 and 18dBu for C AD 3321 OFF =12dBu for C AD 3320 and 15dBu for C AD 3321 Note.
  • Page 21: Alarm/Led Status Indicators

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Alarm/LED Status Indicators The C AD 3320 D / C AD 3321 D module has built in LED indicators that serve as alarm and status indication for the module. Function is described below.
  • Page 22: Front Panel Alarm Indicator

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Front Panel Alarm Indicator There is also a single alarm LED on the front side of the module, (figure2) which is designed for quick and easy indication of a problem condition in installations where visible access to the bottom of the module is not convenient.
  • Page 23: Specifications (C Ad 3320/3321 D)

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Specifications (C AD 3320/3321 D) Analog Input Signal 2x balanced analog stereo inputs Impedance 15kOhm Connection Female SubD 25pin connector Max level 18 dBu (C AD 3320); 24dBu (C AD 3321) 0dB FS level Adjustable (12dBu, 15dBu or 18dBu;...
  • Page 24: Available Options

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Available Options Below is a list of available options for the C AD 3320 D / C AD 3321 D MiniModule. Please refer to product brochures or our web site for more detailed information.
  • Page 25: Parts List

    Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Parts List Due to the very dense design and high level of integration there are no user serviceable electronic assemblies within the C AD 3320 D / C AD 3321 D module.
  • Page 26: Contact Information

    Reference Manual C AD 3320 D / C AD 3321 D Version 1.1 Contact Information Please contact your local distributor; this is your local and fastest method for obtaining support and sales information. LYNX Technik can be contacted directly using the information below.
  • Page 27 Reference Manual C AD 3320 D / C AD 3121 D Version1.1 Notes Page 27...

Table of Contents