Switch Settings

Below the switch settings for the 8-position dip-
switch are defined. Please refer to figure 2 for the
location of the switch.
NOTE. Settings made are applied to both input
channels.
Switch 1
1
2
3
4
Switch 2
1
2
3
4
Page 18
DIP Switch 1
OFF
ON
1 2 3 4
DIP Switch 2
OFF
ON
1 2 3 4
(Connector side)
Setting
Function
ON
Local Control enabled
OFF
Local Control disabled
ON
Select Sample range High (48KHz or 96KHz)
OFF
Select Sample range Low (32KHz or 44.1KHz)
ON
Sample Rate = 44.1KHz or 96KHz **
OFF
Sample Rate = 32KHz or 48KHz **
ON
Test tone ON
OFF
Test tone OFF (normal)
Setting
Function
ON
Select FS 18dBu (EU - C AD 3320)
Select FS 24dBu (US - C AD 3321)
OFF
Select Low FS range (12dBu or 15dBu) (EU)
Select Low FS range (15dBu or 18dBu) (US)
ON
FS range = 15dBu (EU) *
FS range = 18dBu (US) *
OFF
FS range = 12dBu (EU) *
FS range = 15dBu (US) *
ON
Mute channel 1
OFF
Normal operation
ON
Mute channel 2
OFF
Normal operation