Troubleshooting

L E D I n d i c a t o r s
The easiest way to find out the status of your Source Four Revolution fixture is to look at
the LED indicators on the upper enclosure. These LEDs are located on the top of the upper
enclosure when the fixture is sitting on its base. When the fixture is hung on a pipe, the
LEDs are visible to technicians standing below the fixture.
42
No Power
Off
Receiving DMX
On
Signal
Not Receiving
Blinking
(1/second)
DMX Signal
Fast Blinking
Self-Test Mode
(5/second)
a) Green and amber blinking together indicates that there is potential software corruption.
Recycle power. If this indication persists, contact ETC customer service.
b) Red and green blinking together indicates that the thumbwheel address is set higher
than 481. Reset thumbwheel to 481 or lower. See
8
for further information.
Green
Amber
Lamp OK
a b
Lamp Out
LED Location
Green
Red
Calibration
Successful
Calibration in
Progress
- or -
Error
Connections and Addressing, page
Amber
Red