3

3.2.3 Refilling with fuel

A

Reloading intervals

3.2.4 Switching off the system

8
Page 18
B0610008
Touching hot surfaces behind the insulated door!
Risk of burns from hot surfaces!
By the nature of its operation, the surfaces and operating
elements in the area behind the insulated door get hot! When
working with firewood, there is also a risk of injury from splinters.
When working on the boiler during operation, particularly
when reloading fuel, it should be standard practice to wear
protective gloves.
Open the fuel loading door slowly and check the fuel
Has the fuel in the boiler burnt down:
Refill fuel
If there is enough fuel in the boiler:
Close the fuel loading door immediately
The reloading intervals should depend exclusively on the storage tank.
If the temperature of the storage tank above has dropped to a certain
temperature (floor heating: approx. 30-40 °C, radiator heating: approx.
50 °C), reload fuel.
The amount of fuel should be measured so as to ensure that the storage
tank is continuously warmed to the maximum storage temperature
(max. 80-90 °C).
The amount to reload also depends on the type of fuel.
CAUTION! Only when the boiler when it has burnt down and
cooled off.
Switch off the main switch (8) on the control unit
The control is switched off
All the system components are powered down
Operating the system
W A R N I N G
Heating the boiler
I