11. Insert one captive screw through a saddle washer, then insert
the captive screw with the washer on it through the hole in the
DB-25 end of the case. Snap that side of the case closed.
Repeat the process for the other side. This completes cable
installation.
4.2 CONNECTION TO THE RS-232 INTERFACE
Once you have configured the Model 1010B for DTE or DCE and
connected the twisted pair wires correctly, all that remains is to plug the
1010B directly into the DB-25 port of the RS-232 device. After doing so,
remember to insert and tighten the two captive connector screws.
(Note: If you must use a cable to connect the Model 1010B to the
RS-232 device, make sure it is a straight through cable of the shortest
possible length—we recommend 6 feet or less).
4.3 OPERATING THE MODEL 1010B
Once the Model 1010B is properly installed, it should operate
transparently—as if it were a standard cable connection. Operating
power is derived from the RS-232 data and control signals; there is no
"ON/OFF" switch. All data signals from the RS-232 interface are
passed straight through. All control signals from the RS-232 interface
are looped back.
NOTE: If your system requires hardware flow control, you will
need the Patton Model 1012 Modem or Model 1060 Short Range
Modem. Call Patton Technical Services at: (301) 975-1007;
http://www.patton.com; or, support@patton.com.
11
PATTON MODEL 1010B
SPECIFICATIONS
Transmission Format: Asynchronous, full duplex
Transmission Line:
Two unconditioned twisted pair 19 - 26 AWG
Range:
See table on page 13
Interfaces:
EIA RS-232, CCITT V.24
Data Rates:
300 bps - 115.2 kbps
Isolation:
Minimum 1500V RMS using custom
transformers
Surge Protection:
600W power dissipation
Dimensions:
2.66" x 2.10" x 0.73" (67.6 x 53.3 x 18.5)mm
Factory DCE/DTE
DCE (transmits from RS-232 on pin 2)
Setting:
Control Signals:
DSR and DCD follow DTR from the terminal
(DTE); CTS follows RTS from the terminal
(DTE)
Connectors:
DB-25 male or female on RS-232 side;
RJ-11, RJ-45 or terminal block with strain
relief on line side
Power Supply:
None required; uses power from EIA data
and control signals
Temperature Range:
0-50°C (32-122°F)
Altitude:
0-15,000 feet (0-5,000m)
Humidity:
5 to 95% noncondensing
Weight:
2 oz. (56.8 grams)