Construct a two pair cross over cable that makes a connection
between the two short range modems as shown below.
XMT +
XMT -
G
To Shield (Optional)
RCV -
RCV +
6.
If there is a shield around the telephone cable, it may be
connected to "G" on the terminal block. To avoid ground
loops, connect the shield at the computer end only. A ground
wire is not necessary for proper operation of the Model
1010B.
7.
Refer to the diagram below to confirm that you have correctly
assembled the device.
8.
Place the 2 halves of the strain relief assembly on either side
of the telephone wire and press together very lightly. Slide the
assembly so that it is about 2 inches from the terminal posts
and press together firmly. If your cable diameter is too small or
too large for our strain relief, please contact our technical
support. We have strain relief assemblies to accommodate
most cable diameters.
9
}
RCV+
One Pair
RCV -
G
XMT -
}
One Pair
XMT +
9.
Place the wires through the strain relief assembly. Then, insert
the strain relief assembly into the slot in the bottom half of the
modem case and set it into the recess in the case.
10. BEND the top half of the case as necessary to place it over the
strain relief assembly. Do not snap the case together yet.
10