Electrical Requirements For Battery Charging; Amperage And Breaker Parameters; Charge Station Mounting Instructions - Bosch Power Xpress Installation And Operating Instructions Manual

Charge station
Table of Contents

Advertisement

en | 8 | Installation and Operating Instructions | Power Xpress Charge Station
Electrical Requirements for
Battery Charging
WARNING: The Charge Station must
be installed by a licensed electrician
in accordance with all national and
local
electrical
requirements, and all authorities having
jurisdiction.
CAUTION: The AC electrical connection
must have a grounded, dedicated service-
main. No other loads shall be connected to
the same circuit. Use of a non-dedicated
circuit could exceed the current rating of
the circuit breaker and cause it to trip or
open.
CAUTION: Do not use portable or stationary
backup generating equipment to charge
the vehicle. This may cause damage to the
vehicle's charging system. Only charge the
vehicle from utility-supplied power.
Amperage and Breaker
Parameters
Note:
The Charge Station has been factory set at 30-amp
output for a 40-amp circuit. For all other amperages:
1.
Remove the domed cap from the current-adjust-
ment selector (positioned just above the reset
button on the front of the Charge Station).
2.
Using a small, flat-blade screwdriver, set the cur-
rent-adjustment selector to the applicable output
current-limiting setting, as indicated in Table 1 or
Table 2.
EL -50600-7-2 | REV. B | 20.10.2013
codes,
ordinances,
Table 1. North American Current-Adjustment Settings
Charge
Charge
Station
Breaker
Station
Current-
Required,
Output,
Adjustment
Amp
Amp
Setting
1
12
2
16
3
24
4
32
5
30
Table 2. European Current-Adjustment Settings
Charge
Charge
Station
Breaker
Station
Current-
Required,
Output,
Adjustment
Amp
Setting
1
13
2
16
3
20
4
32
5
30
*Line service breaker; not appliance service breaker
Note:
Only settings 1–5 are operational. Settings 6, 7, 8, 9, and
0 are not used, and the Charge Station will not function
under these settings.
Charge Station Mounting
Instructions
WARNING: Read all instructions before
installing the Charge Station.
Identify an approximate mounting location for the Charge
Station that is within 10 feet (3 m) of the vehicle's charg-
ing inlet.
Determine the power source location.
CAUTION: Verify there is no existing
infrastructure behind the selected wall
(wiring, plumbing, ductwork, pipes, etc.)
Follow the appropriate instructions for your installation:
"Finished Wall Charge Station Installation" on page
9
"Masonry Wall Charge Station Installation" on page
13
"Molded Plug-Connected Charge Station Installation
(North America only)" on page 16
Note:
If wall surface is unfinished (studs only), mount a 36 ×
17.5 × 3/8-in. (90 × 45 × 1-cm) plywood surface between
the studs and securely fasten in place. Follow "Finished
Wall Charge Station Installation" for mounting and "Ma-
sonry Wall Charge Station Installation" for wiring.
NEMA
Wire
Receptacle
Required,
Required
Gauge
(plug-in
version)
15
12
6-15
20
12
6-20
30
10
6-30
40
8
6-50
40
8
6-50
Wire
Required,
Amp
mm
2
16
3.31
20
3.31
20*
5.26
40
8.36
40
8.36
Bosch Automotive Service Solutions LLC