Cleaning or replacing the air filters
1 Disconnect the fixture from power. On each side of the head, remove the 2 screws that hold the side cover
using a Torx-20 screwdriver. Slide the cover forward to remove. Lift the filter off of the cover.
2 Clean the filters with a vacuum or compressed air. If they are saturated with smoke residue or other
contaminants, soak them in warm soapy water and blot dry. Replace any filter that is damaged or
impossible to get perfectly clean.
3 Place the filters on the covers and replace the covers.

Software installation

The factory-installed software version is indicated on the serial number label. The currently installed
software version number is displayed in the control panel during power-on and in the
Software updates are released when features are added. The latest MAC 2000 Wash software is available
for download from the Support area of the Martin website at http://www.martin.com.
Requirements
Software can be installed using a PC connected to the fixture via a data link using one of the following DMX
interface hardware devices:
• Martin DABS 1™, currently available with the Martin MUM™ (Multi Utility Manager) software package
• Martin Universal USB-DMX Interface Box™
• ShowDesigner™ PCI DMX Interface Card (2048 channel version)
• Martin LightJockey™ PCI DMX Interface Card (512 and 2048 channel versions)
Besides one of the hardware devices listed above, the Martin Software Uploader program, version 5.5 or
later, is required. The Software Uploader program is supplied with the MUM and LightJockey programs, as
well as with DABS1 hardware devices. It is also available for download from the Support area of the Martin
website at http://www.martin.com.
Note: If intermediate control systems such as the Martin Lighting Director™ (MLD) and the Martin Matrix™
are present, they must be bypassed when updating fixture software via the DMX link. These systems do not
relay the update code correctly because the code is not DMX-compliant.
Standard software installation
For guidance on preparing and using your hardware device and the Software Uploader program, refer to the
user documentation and/or online help for these products.
What to do if the standard software installation fails
If the normal upload procedure does not work, or if the software update notes call for a boot sector update,
move the boot sector jumper at PL16 to the BOOT position before uploading software.