Advancedprogramming Tips - HP 7470A Interfacing And Programming Manual

Graphics plotter
Hide thumbs Also See for 7470A:
Table of Contents

Advertisement

AdvancedProgramming Tips
Many software packages read P1 and P2 and use these points to define
the maximum plotting area. You may want to obtain the largest plot
possible on the 7470. This is the area of the default window, as deter­
mined by the setting of the paper switch, not the area established by
the default settings of P1 and P2. The first three lines of the following
listing will read the window size and set P1 and P2 to these points, so
that the largest area possible is used for plotting. In order to change the
plotting area, this HP-GL routine should precede the PLOTTER IS
statement when programming on HP desktop computers in AGL.
Sometimes you want more than one plot on a page. The rest of the
instructions set the window to, and outline four separate areas. A small
space has been left between each area by adding or subtracting a
constant value from X— and Y—coordinates in the center of the total area.
This program could be modified to divide the plotting area into thirds
or into areas of any other size. Another application of windowing is
shading rectangular areas for bar graphs. See Advanced Programming
Tips, Chapter 8.
"IN;DN"
!INSERT LINE T0 REHD CUDRDIHHTES INTO H,B,C,D
"IP";H,B,C,D
"IN";H,E;C/2-100;D/2-100;"SP1;PH";H;B
"PD";C/2-100;B;C/2-100;D/2-100;H;p/2-100;H;B;"PU"
"IN";C/2+100;B;C;D/2—100;"SP2;PU";C/2+100;B
"PD";C;B;C,D/2-100;C/2+100;D/2-100;C/2+100;B;"PU"
"IN";C/2+100;D/2+100;C;D;"SP1;PH";C/2+100;Dx2+10O
"PD";C;D/2+100;C;D;C/2+100;D;C/2+100;D/2+100;"PU;"
"IN";H;D/2+100;C/2-100;D;"PU;SP2;PH";H;D/2+10O
"PD";C/2-100;D/2+100;C/2—100;U;H;D;H;D/2+100;"SPO;"
Reduced Plot
ESTABLISHING BOUNDARIES AND UNITS 2-11