Installation; Installation Warning; Packing List; Additional Items Required For Installation - Travis Industries 35 CB Australian Owner's Manual

Direct vent fireplace
Table of Contents

Advertisement

6
Installation Warnings:
!
This appliance shall be installed in accordance with the manufacturer's installation
instructions, local gas fitting regulations, municipal building codes, electrical wiring
regulations, the AGA gas installation code and any other relevant statutory
regulations.
!
Failure to follow all of the requirements may result in property damage, bodily
injury, or even death.
!
This fireplace must be installed by a qualified installer who has gone through a
training program for the installation of direct vent gas appliances.
!
This appliance must be installed in accordance with all local codes, if any; if not, in
U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow B-149.
!
The 35 CB is designed to operate on natural gas or propane (LP).
!
All exhaust gases must be vented outside the structure of the living-area.
Combustion air is drawn from outside the living-area structure.
!
The requirements listed below are divided into sections.
met simultaneously.
should follow the procedure best suited for the installation.

Packing List

Propane Conversion Kit
Log Set (Log Set, Coals, & Glowing Embers)
Flex Tube with Pipe Adapter
Glass Latch Tool (to un-latch glass frame)
Black 35 CB Face (with touch-up paint)
Cove Covers

Installation Overview

See the section
"Mantel Requirements"
8-1/2" Min.
(216 mm)
(fr. glass frame)
See the section
"Electrical
Connection"
See the section
"Hearth Requirements"
Travis Industries

Installation

The order of installation
Drywall
See the section
"Gas Line Installation"
(for qualified installers only)
is not rigid – the qualified installer
Additional Items Required
Direct Vent (Simpson Dura-Vent Ph. # 800 835-4429)
Gas Line Equipment (shutoff valve, pipe, etc.)
Electrical Equipment (min. 18 gauge, grounded line)
See the section
"Vent Requirements"
9 3 5 0 8 1 3 4
All requirements must be
See the
section
"Acceptable
Vent Lengths"
Insulation must not fill
the spaces between
the stand-offs
See the section "Minimum
Framing Dimensions"
4 0 3 0 6 2 4