Saturated Properties; System Operation; Heat Pump Flow Diagram; Demand Defrost Control Module - Johnson Controls 13 SEER - THGD Installation Manual

R-22 outdoor split-system heat pump 13 seer 1.5 to 5 tons
Table of Contents

Advertisement

359513-UIM-A-0408
TABLE 1: R-22 Saturated Properties
Pressure
Pressure
Temp °F
PSIG
PSIG
80
48
110
82
49
112
84
50
114
86
51
116
88
52
118
90
54
120
92
55
122
94
56
124
96
57
126
98
58
128
100
59
130
102
60
132
104
61
134
106
62
136
108
63
138
CHARGE COMPENSATOR
(Empty in cooling / full in heating)
(Not included in all Units)
OUTDOOR
COIL
LIQUID
SENSOR
COOLING CYCLE FLOW
HEATING CYCLE FLOW
FIGURE 10: Heat Pump Flow Diagram
DEMAND
DEFROST CURVE
X/L
SELECTION JUMPER
R
C
Y
O
W
W1/66
FIGURE 11: Demand Defrost Control Module
10
Pressure
Temp °F
PSIG
64
140
65
142
66
144
67
146
68
148
69
150
70
152
71
154
72
156
73
158
74
160
75
162
76
164
77
166
78
168
SHOWN IN COOLING POSITION.
** NOTE: The indoor coil is shipped with an orifice. The orifice must be replaced with a TXV Kit.
P
TEST
1
2
3
4
PRESSURE
REV
VALVE
SWITCH
M
Pressure
Temp °F
Temp °F
PSIG
78
170
91
79
172
91
80
174
92
81
176
93
82
178
94
83
180
94
84
182
95
84
184
96
85
186
97
86
188
97
87
190
98
88
192
99
88
194
99
89
196
100
90
198
101
FIELD CONNECTED LINE
4-WAY
REVERSING
VALVE
FILTER DRYER
(Solid core)
COMPRESSOR
SUCTION
ACCUMULATOR
BI-FLOW
TXV/CHECK
VALVE OR ORIFICE (Heating)
SECTION VIII: SYSTEM OPERATION
ANTI-SHORT CYCLE DELAY
The control includes a five-minute anti-short cycle delay (ASCD) timer
to prevent the compressor from short cycling after a power or thermo-
stat signal interruption. The ASCD timer is applied when the control is
first powered from the indoor unit thermostat and immediately following
the completion of a compressor run cycle. The compressor and the out-
door fan will not operate during the five minutes that the timer is active.
The ASCD timer can be bypassed by connecting the TEST terminals
for three seconds while the thermostat is calling for compressor opera-
tion (Y input signal energized).
Pressure
Pressure
Temp °F
PSIG
200
101
202
102
204
103
206
103
208
104
210
105
212
105
214
106
216
107
218
107
220
108
222
109
224
109
226
110
228
111
INDOOR COIL
BI-FLOW
TXV/CHECK
VALVE (Cooling) **
FIELD CONNECTED LINE
Johnson Controls Unitary Products
Temp °F
PSIG
230
111
232
112
234
112
236
113
238
114
240
114
242
115
244
115
246
116
248
117
250
117
252
118
254
118
256
119
258
119