Moving Valve to Other Side of Fireplace

The Valve Assembly may be changed to the other side of the fireplace.
This must be done Before the unit is inside the enclosure.
1.
Remove the Burner Tube (See Burner Tube Removal section in this Manual).
Disconnect plumbing from the valve, including connections to Pilot. Remove the [4] DT screws in the burner pan
2.
which hold the Valve System in place. Reinstall with the Valve System on the other side of the fireplace. Reconnect
plumbing, along with Pilot. These connections must be leak tested.
3.
Remove the Electrical Box and Light Power Bus Module (and IPI Module & IPI Shield if used), and locate these
items to the other side of the unit.
4.
Replace the Burner Tube.