3.5 Initial Unit Setup

Some of the iPump's settings are preconfigured or should be configured during
the iPump's initial setup and are not likely to require adjustment on a regular
basis. RF current channel, date and time, and unit label settings should be made
at this time.
Initial RF
A few of the RF settings are preconfigured and should only be changed if
setup
advised by your satellite operator. These include the LNB LO value, SNR
Alarm Threshold, and SNR Margin Warning settings. The table bleow lists
these settings as they are configured on your iPump when it is delivered from
the factory.
(appropriate for Ku-band reception -
5150 MHz would be an appropriate setting for
C-band operation)
(signal-to-noise ratios below this value will
result in an alarm condition)
(warning condition triggered when signal-to-
noise ratio is within 3.0 dB of the SNR Alarm
Threshold - under 8.0 dB as preset)
Current
Navigate to the RF Setup screen.
Channel
Setup
Step
wegener.com
Table 8: iPump Preconfigured RF Settings
Parameter
LNB LO Value
SNR Alarm Threshold
SNR Margin Warning
Press
a)
UNIT SETUP
b)
ENTER
RECORD AND PLAY
Preset Value
10750 MHz
Displayed
31
iPump User's Manual
5.0 dB
3.0 dB