Alarm Connector Details; Table 4 Ipump Connector Details - Wegener iPump User Manual

Media server/store and forward receiver
Hide thumbs Also See for iPump:
Table of Contents

Advertisement

Connector
Designation
Type
RF IN
female Type F
ASI IN
female BNC
AUDIO
1/8-inch stereo
jack
AUX AUDIO
1/8-inch stereo
jack
VIDEO
BNC
LAN
female RJ-45
CONTACT
male DB-9
CLOSURE/
ALARM
POWER
Male IEC recep-
tacle
Alarm
The DB-9 alarm connector has the following pin functions:
Connector
Details
Pin Number
wegener.com
Table 4: iPump Connector Details
Signal Description
950 to 2150 MHz RF carrier
from antenna LNB
ASI input signal
Audio output
Audio output
S-video, video output
10/100baseT Ethernet
Contact closure/opening in and
out
100-to-120 Vac @60 Hz or
200-to-240 Vac @ 50 Hz
Table 5: iPump Alarm Connector Pin Functions
1
Alarm common
2
Alarm Normally Open
3
Contact Closure Out Common
4
No Connection
5
Contact Closure Input
Additional Information
A extension cable is shipped already
attached to the RF IN port to allow
easier access for attaching your RF
input.
Only on iPumps with the ASI input
option.
A 1/8-to-RCA adapter is shipped
with your iPump (one for each active
audio decoder).
Can be "slaved" to decoder 1 or
decoder 2
A SVD-to-RCA adapter is shipped
with your iPump. Units equipped
with the optional, professional 4:2:2
decoders will have a female BNC
connector.
Autosensing; see pinout detail
Table 6: iPump LAN Con-
in
nector Pin Functions
page 20
See pinout detail in
iPump Alarm Connector Pin
Functions
Autoswitching
Function
19
iPump User's Manual
on
Table 5:
on page 19
800009-01 Rev. A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents