pressure reducer must NOT be installed in
the body interior. Moreover, it should be
located in a well-ventilated area.
It is recommended to check the vehicle low
pressure gas pipe flow rate.
Insufficient flow rate would activate the safety
valve (Secumotion type), when the generator is
being started or while it is functioning.
Please note that the flow rate indicates the
quantity of gas delivered over a period of time
(Kg/h) whereas the pressure is the gas force
(Bar).
The gas hose (Fig. 15 Ref. 5) which directly
connects the pressure reducer and the gas bottle
(Fig. 15 Ref. 3) is not supplied.
For this connection, the installer will use a
suitable type-approved hose which is equipped
with the suitable fittings.
in Fig. 16 are FORBIDDEN on both the
reducer and the gas bottle.
Fig. 17 shows proper connection, with a suitable
hose on which the fitting (6) is tightened.
Fit the ogive (7), hold the fixed hexagon ring (8)
by means of a wrench and tighten the ring nut
(9).
Vers. 001
Remember
that
Connections as shown
Energy 2510 G
GB
the
generator in cold environments, please
remember that the lower the temperature
(down to a temperature limit of – 15°C),
the higher the percentage of propane gas
which is recommended
4.10

Battery charger

ENERGY 2510 G generating sets are equipped
with a battery charger which can deliver current
of approximately 10 Amp at 12 V. It can be used
to recharge the generating set start-up battery.
To obtain this function, use a 2,5 mm
section cable to connect the terminal identified by
CHARG (Fig.19 Ref. 1) to the positive pole (red
cable) of the generating set (Fig. 19 Ref. 2)
possible to use the 12 Volt alternating current
output provided on the bipolar connector shown
in Fig. 13 Ref. 6 .
4.11

Auxiliary Battery Charger

If you wish to recharge a different battery or do
not wish to use the CHARG terminal, it is To
these two Faston terminals,
section cables should be connected to obtain
interfacing to an optional RCB regulator (code
05424) as shown in Fig. 20.
not autonomously recharge the battery used
for starting-up unless this is connected to a
battery charger.
When using the
2
cross-
4 sq.mm cross-
The generating set will