7.2 Maintenance not requiring specialised
personnel
To perform this kind of service, it will be
necessary to open the generating set door. The
following precautions must therefore be taken:
1 The generating set must not be in operation,
and all its parts must be cold
2 Let the generating set cool off.
3
Turn the selector switch to the position "ON"
(manual) (Fig.31 Ref.2)
N.B. Remember to switch the selector switch
to "OFF" (automatic) after completing the
required checks.

7.3 Checking the engine oil level

Unscrew the engine oil filler cap and clean the
dipstick (Fig.33 Ref.1).
Put the dipstick back in without screwing.
Take the dipstick out again, and make sure
that the engine oil level is between the two
(min and max) notches. Should the oil level be
below the minimum notch, restore the oil level
using the recommended type of engine oil
(refer to the engine user and maintenance
manual).
Put the dipstick and filler cap back on and
screw tightly.
Do not fill to exceed the
maximum
level,
malfunctioning of the fuel pump and hence of
the generating set.
checking operations must be performed with
the generating set in a perfectly horizontal
position.
Vers. 001
as
this
could
cause
All engine oil level
Energy 2510 G
GB
7.4 Maintenance operations to be carried out
by qualified personnel
To carry out certain servicing operations, it is
possible
to
extract
assembly from the front. (See paragraph 4.3.).
This will make it easier to obtain access to all the
inside parts of the generating set for unscheduled
maintenance or repair operations.

7.4.1 Engine oil replacement

Use multigrade detergent oil for four-stroke petrol
engines having a SAE viscosity degree suited to
the climate the generating set is working in (see
table and detailed instructions in the engine use
and maintenance manual).
For hot climates
For cold climates
To make it easier to drain the spent engine oil, it
is advisable to let the engine run for 3 - 5
minutes; in this way, the oil will be more fluid and
emptying will be quicker and more thorough.