Step 8 —Calibrate the Scanner
During the calibration routine, the scanner attempts various settings
to determine the optimum decode rate for the given conditions. In this
process it might do the following:
• Adjust laser power
• Adjust mirror motor speed
• Adjust AGC gain
• Enable Autodiscrimination
(read several symbol types)
The test will end automatically when the optimum combination of
settings has been achieved.
By ESP
Click the
Calibrate
begin the read rate test.
You can observe the progress of the calibration
routine on the Calibration popup.
Note: You can also use the Calibration menu in App Mode.
By EZ button
Press and hold the
until you hear two beeps and
see two performance LEDs
turn amber to indicate that the
calibration is in progress.
The scanner will beep once
at the end of calibration.
10
button in Setup Mode to
Test
button
MS-3 Laser Scanner Quick Start Guide
EZ Button
Read rate
performance
LEDs
Calibration
TEST
100%
GR
80%
ST
60%
40%
20%
PWR
11-000063-01