1150 overhead gate operator ● installation guide

Advertisement

Table of Contents
loading

Summary of Contents for DKS 1150

  • Page 1 1150 overhead gate operator ● installation guide...
  • Page 3: Table Of Contents

    .....................4 glossary ........................6 DKS DoorKing, Inc. specifications ......................7 120 Glasgow, Avenue Inglewood, Ca. 90301 hardware installation rail ..........................8 310.645.0023 operator ........................9 310.641.1586 fax alternate mounting ....................10 www.doorking.com gate arm ........................11 info@doorking.com manual release ......................12...
  • Page 4: General Information Safety Information

    Failure to adhere to posted speed limits can result in damage to the gate, gate operator, and to the vehicle. Save these Instruction for future reference 4 installation guide 1150-065-B-05-07...
  • Page 5 One or more contact sensors shall be located No other activation device shall be connected. at the bottom edge of a vertical barrier (arm). 1150-065-B-05-07 installation guide 5...
  • Page 6: Glossary

    ENTRAPMENT – The condition when an object is caught or held in a position that increases the risk of injury. 6 installation guide 1150-065-B-05-07...
  • Page 7: Specifications

    The 1150 overhead gate operator is designed for high traffi c underground parking applica- tions serving gated communities, apartment complexes, commercial buildings and industrial sites. This operator is not designed for residen- tial applications and should never be used to operate overhead sectional garage doors.
  • Page 8 CHAIN ADJUST Locate the chain adjustment bolts on the rail as- sembly and make the necessary adjustments. Do not over-tighten the chain. Make chain adjustments equally on both sides of the rail assembly. CHAIN 8 installation guide 1150-065-B-05-07...
  • Page 9 Check oil level, add Mobil oil SHC-624 or equivalent and install breather cap. HEADER BRACKET IMPORTANT: Do not fi ll gearbox to top, gearbox should be half full only. GATE BRACKET BREATHER CAP 1150-065-B-05-07 installation guide 9...
  • Page 10: Alternate Mounting

    DOORKING does not provide the ceiling extension bracket, it must be fabricated according to building requiremnets. Isolate the bracket from the ceiling using rubber shock mounts Check all local building codes and ordinances to ensure compliance. 10 installation guide 1150-065-B-05-07...
  • Page 11: Gate Arm

    Attach the arm assembly to the gate bracket and carriage assembly as shown. Manually raise and lower the gate, be sure the gate is operating smoothly and is not binding anywhere. Any interference must be corrected now. PULL DOWN TURN C O U N T E R CLOCK-WISE 1150-065-B-05-07 installation guide 11...
  • Page 12: Manual Release

    To lock the carriage assembly for automatic operation, slide the carriage below the master link until you hear a loud click. Slide the the ring back in to place and lock the the carriage. Master Link Carriage 12 installation guide 1150-065-B-05-07...
  • Page 13: Power Switch

    The operator ON or OFF power switch is located on the back of the operator. 1150-065-B-05-07 installation guide 13...
  • Page 14: Electrical Installation Main Terminal Description

    13. DRY RELAY CONTACT 14. 24 VAC, 250 MA MAXIMUM 15. NOT USED 16. POWER OUTPUT TO MOTOR 17. POWER OUTPUT TO MOTOR 18. 120 VAC HOT 19. 120 VAC NEUTRAL 20. EARTH GROUND / CHASSIS 14 installation guide 1150-065-B-05-07...
  • Page 15: Wiring Diagram

    1150-065-B-05-07 installation guide 15...
  • Page 16: High Voltage

    10 AWG 8 AWG 6 AWG 1150-08X The distance shown above is measured in feet from the operator to the power source. If power wiring is greater than the maximum distance shown, it is rec- ommended that a service feeder be installed. When large gauge wire is used, a separate junction box must be installed for the operator connection.
  • Page 17: Control Wiring

    Connect optional control devices to the main terminal strip. Use 18 AWG wire for all low voltage wir- ing, maximum distance 3000 feet. Use a low voltage surge suppressor, (DoorKing P/N 1878-010) if low voltage wire runs exceed 1000 feet. All inputs to the terminal strip must be NORMALLY OPEN. 1150-065-B-05-07 installation guide 17...
  • Page 18: Entrapment Protection

    (sensors may require seperate power depending on model used). If high bed vehicles access the gate, a second photo-cell should be placed so that the photo-beam cannot scan under the vehicle. Photocell Receiover/Reflector Photocell Sender 18 installation guide 1150-065-B-05-07...
  • Page 19 Connect the sensors to the main terminal strip, sensing edge to circuit board is NORMALLY OPEN. Sensing edge installation is not shown, refer to hardware in- structions included with hardware. Position and wire sensors avoiding communication loss and mechanical damage. See page 26 for sensor adjustment. Junction Edge Sensor 1150-065-B-05-07 installation guide 19...
  • Page 20: Loop Detector

    If using other loop detectors, all inputs to the terminal strip are NORMALLY OPEN. Use a separate power supply to power external detectors. Power must be turned off before connecting to the terminal strip. Refer to the separate Loop Information Manual (Loop Info Rev. G 3-02) when installing loops or preformed loops. 20 installation guide 1150-065-B-05-07...
  • Page 21: Gate Tracker

    Maximum wire run for gate operator to tracker board is 500 ft. using Belden #9931 shielded cable or Consolidated #5324-CL shielded cable. Float the shield at the tracker board. Do not connect the shield to the tracker board common. For more Gate Tracker™ information refer to the installation/Wiring Manual, P/N 2351-010. 1150-065-B-05-07 installation guide 21...
  • Page 22: Auxiliary Stop

    Connect the stop switch to terminals 1 and 9. Place a jumper wire from terminal 8 to terminal 9. This circuit cannot be used if a DoorKing 3 button control station is connected to the operator. 22 installation guide 1150-065-B-05-07...
  • Page 23: Settings Control Board

    Input LEDs should be OFF and will only illuminate when the input is activated. The limit LED will be ON when the respective limit switch is activated. Any attempt to force the gate open will turn on the Gate Forced LED. 1150-065-B-05-07 installation guide 23...
  • Page 24 Sets the circuit board to function with slide gate operators (switch OFF) or overhead gate operators (switch ON). This switch must be left in the ON Overhead Gate position for model 1150 Overhead Gate Operator. Spare Spare – leave switch in the OFF position.
  • Page 25 After adjusting the limit-nuts, re-engage the lock plate in the slots on the limit-nuts to prevent them from slipping. Turn power on and activate the gate operator. Re-adjust the limit-nuts as necessary for full-open and full- close gate travel. 1150-065-B-05-07 installation guide 25...
  • Page 26 “soft shutdown” making it necessary to initiate the cycle again by momentarily shorting terminals 1 and 5 as in step 1 to reactivate the automatic close timer. 26 installation guide 1150-065-B-05-07...
  • Page 27: Technical Information Maintenance Schedule

    If reversing devices are not functional and cannot be placed in an operable state, DO NOT PLACE OPERATOR IN SERVICE. If the operator is equipped with a battery back-up system, follow the steps below to check the operation of this system. 1150-065-B-05-07 installation guide 27...
  • Page 28: Troubleshooting

    Replace with a known good detector and re-check. If problem continues, control board may be bad. the wire size chart on page 16. reverse gate. · If loop detector LED does not illuminate, see above. 28 installation guide 1150-065-B-05-07...
  • Page 29: Accessories

    The following accessories can be used with the model 1150 overhead gate operator. Contact Sensor Contact sensors for use as a secondary entrapment protection device. Miller Edge, Inc. ME120, ME123, MG020, MGR20, MGS20 Photo Cell Non-contact (photo cells) sensors for use as a secondary entrapment protection device.