Cables Required - Paradyne FrameServer SLV 9520-ILM Installation Instructions Manual

Hide thumbs Also See for FrameServer SLV 9520-ILM:
Table of Contents

Advertisement

Cables Required

Table 1, Cables
Required, shows the cables used with the FrameSaver SLV 9520-ILM.
See the
FrameSaver SLV Technical Description (9000-A2-GB30)
specifications of the cables.
Table 1. Cables Required
Port
Cable Description
NET RX,
BNC to BNC coaxial
NET TX
and
CPE RX,
CPE TX
LAN
Ethernet 10/100BaseT
straight-through cable with
8-pin modular connectors
Ethernet 10BaseT crossover
cable with 8-pin modular
connectors
Modem
RJ11 to RJ11 modular
Maximum Cable Lengths
Table 2, Maximum Cable
which a maximum is specified.
Table 2. Maximum Cable Lengths
Cable Description
Ethernet 10/100BaseT unshielded twisted pair with 8-pin
modular connector
DB25-to-DB25 EIA-232-F for terminal
Lengths, shows the maximum distances for each cable for
Quantity Required
Four
One (if LAN port is to be
connected to an
Ethernet hub)
One (if LAN port is to be
connected to a Network
Interface Card)
One
4
for electrical
Supplied
Two
No
No
No
Maximum Length
328 ft (100 m)
100 ft (30 m)