EXHAUST TEMPERATURE GAUGE (OPTIONAL)
A four point gauge may also be fitted which
measures the exhaust temperature of both
banks
before
as
turbocharger (see Fig. 25 and Fig. 26).
NOTE: These gauges are wired with 'A'
bank defined as 'the left hand bank as
viewed from the FRONT (free end) of the
engine'.
With both the above gauges, a thermocouple
is inserted into each exhaust at the point to
be measured, and is connected via armour
braided cable to a nylon terminal connector.
Type K compensating cables are used to
connect the nylon terminal connector to the
gauge. (see
Fig.
22).
Wiring is quite straightforward, with the
positive (red) terminal on the nylon terminal
connector, connected to its corresponding
positive (red) terminal at the back of the
gauge (see
Figs. 22, 24
Key
(Fig. 26)
1
24V DC Suppy
38
well
as
after
the
and 26).
Fig. 25
Fig. 26
4012/16 Diesel, February 1997