Optional Equipment
10. Remove the four screws holding the control cover in place (see picture below). Pull the control cover forward
slightly and disconnect the flame height knob (do not remove the knob). This allows the control cover to move
upwards, away from the concealment cover.
11. Pull the control cover forward, taking care to not damage any wiring (see picture below). This will allow access
to the gas control valve.
12. Use a T-20 torx wrench to remove the stock regulator (see picture below). This item may be discarded.
13. Replace the regulator following the instructions included with the regulator kit. Remove and discard the screws
(see "a" below) holding the stock regulator in place (see "b" below). Remove the stock regulator and gasket
(see "c" below). Place the LP regulator in place, making sure the pre-fitted gasket (see"c" below) is in place –
make sure it is correctly oriented. Secure using the screws included with the motor – tighten to 25 Lb-inches.
Leak test this area after installation to verify proper installation. There is a label on the base of the
regulator knob indicating regulator type (NG or LP). Place the included label on the valve body where it can be
easily seen to insure proper identification ("d").
14. Replace the firebox components.
15. Restore the appliance to the correct configuration. Make the gas line connection, bleed the gas line (if
applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve.