Travis Industries DVS GSR2 NB Insert Owner's Manual

Direct vent fireplace insert
Hide thumbs Also See for DVS GSR2 NB Insert:
Table of Contents

Advertisement

WARNING: If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of
life.
-
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire department.
-
Installation and service must be performed by a qualified installer, service agency or the
gas supplier.
This appliance may be installed in an
aftermarket, permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local
codes.
This appliance is only for use with the
type(s) of gas indicated on the rating
plate. A conversion kit is supplied with
the appliance.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
 Copyright 2014, T.I.
· DVS GSR2 NB Insert ·
 Direct Vent Fireplace Insert
 Masonry or Factory Built (Metal) Wood-
 Natural Gas or Propane
$10.00
100-01295
Owner's Manual
Tested and Listed by
ANSI Z21.88 CSA 2.33
Burning Fireplace
Residential or Mobile Home
4140429
Travis Industries, Inc.
www.travisproducts.com
12521 Harbour Reach Drive
Mukilteo, WA 98275

Advertisement

Table of Contents
loading

Summary of Contents for Travis Industries DVS GSR2 NB Insert

  • Page 1 · DVS GSR2 NB Insert · Owner's Manual Tested and Listed by ANSI Z21.88 CSA 2.33  Direct Vent Fireplace Insert  Masonry or Factory Built (Metal) Wood- Burning Fireplace  Natural Gas or Propane  Residential or Mobile Home...
  • Page 2: Introduction

    This serial number will be needed in case you require Or, mail your warranty card to: service of any type. Travis Industries House of Fire 12521 Harbour Reach Drive Model: DVS GSR2 NB Mukilteo, WA 98275 Serial Number: Save Your Bill of Sale.
  • Page 3: Table Of Contents

    CONDITIONS & EXCLUSIONS ...... 40 Glass Frame Removal and Installation     (continued) ............22 IF WARRANTY SERVICE IS NEEDED: ..40     Steps for Finalizing the Installation ..... 23 LP Conversion Instructions ......41 © Travis Industries 4140429 100-01295...
  • Page 4 Immediately call a qualified vicinity of this heater. service technician to inspect the appliance and to replace any part of the control system that has been under water. © Travis Industries 4140429 100-01295...
  • Page 5 Always follow the logs). instructions in this manual. • If the fiber logs become damaged, replace with Travis Industries log set.  Young children should be carefully • Plug the heater into a 120V grounded electrical outlet. Do supervised when they are in the not remove the grounding plug.
  • Page 6: Features

    This heater is shipped in natural gas (NG) configuration but may be converted to use propane (LP) using a conversion kit. The sticker on top of the gas control valve will verify the correct fuel. © Travis Industries 4140429 100-01295...
  • Page 7: Installation Warnings

    Packing List   LP Conversion Kit (Orifices, etc.) Cover Plugs for 3-Piece Surround Panels   Cove Covers Remote Control   “Fireplace Altered" tag (attach to the fireplace) Top Convection Deflector © Travis Industries 4140429 100-01295...
  • Page 8: Additional Items Required

    Connect the gas line and gas vent to the appliance. Install the optional surround panels and trim. Install the burner and media (logs and stones). Follow the instructions under "Finalizing the Installation" on page 23. © Travis Industries 4140429 100-01295...
  • Page 9: Top Convection Deflector

    Attach the “This fireplace has been altered…” plate to the fireplace (use two screws or other suitable method). You may wish to place it in a location where it will be covered by the surround panels. © Travis Industries 4140429 100-01295...
  • Page 10: Factory-Built (Metal) Wood-Burning Fireplace Requirements

    The heater and face must not contact combustible surfaces. A non-combustible hearth extension is not required. However, if the heater is installed next to the floor, we recommend a hearth to protect the flooring surface from discoloration or other negative impact from the heater. © Travis Industries 4140429 100-01295...
  • Page 11: Leveling Bolts

     The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. © Travis Industries 4140429 100-01295...
  • Page 12: Clearances

    The Discovery, Rosario, and Artisan face require re-positioning of the face connector. See the directions below for details. Remove the face connector bracket Re-attach the face connector to the from the heater (on both sides). heater using the forward mounting holes. Face Connector Bracket © Travis Industries 4140429 100-01295...
  • Page 13: Gas Line Requirements

    The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the suggested input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure. © Travis Industries 4140429 100-01295...
  • Page 14: Vent Requirements

    Installation (for qualified installers only) Vent Requirements Travis Industries manufactures a vent kit specifically for this insert (sku 96200330). It includes 30’ (10M) of vent, hose clamps, and a prairie cap. The flashing on the cap is 18” (458mm) by 18” (458mm).
  • Page 15: Vent Restrictor

    Position 1 (factory setting). Position 2 Vent Installation Secure the vent to the fireplace insert and termination kit using screws. Inlet (3" 76mm) Exhaust (3" 76mm) 3" (76mm) dia. Gas Liner Duravent Chimney Liner Termination Kit Inlet Exhaust © Travis Industries 4140429 100-01295...
  • Page 16: Vent Location

    Before installing the appliance using this method, contact the Authority Having Jurisdiction to determine if this installation is acceptable in your area. This type of installation requires a minimum chimney cross section of 48 square inches. © Travis Industries 4140429 100-01295...
  • Page 17: Vent Connector Removal And Installation

    4. Slide the insert into place, guiding the vent connector into the guides on top of the insert. 5. Attach the vent connector to the appliance (see the following page for details). 6. Remove any excess slack in the flex line and attach the vent termination. © Travis Industries 4140429 100-01295...
  • Page 18: Vent Connector Removal And Installation (Continued)

    Pull on the vent connector rod until the vent connector snaps into place. Slide the vent connector rod in to conceal it. © Travis Industries 4140429 100-01295...
  • Page 19: Surround Panel Installation

    This keeps the trim tight against the panel. panel Optional Knock-Out An optional knock-out is provided if the power cord is routed behind the surround panel. © Travis Industries 4140429 100-01295...
  • Page 20: 1-Piece Surround Panel

    Otherwise, route the power cord behind the panel to the right side (the panel or fireplace may be notched, if required). Installation 1. Attach the mounting brackets as shown below. 2. Attach the surround panel as shown below. © Travis Industries 4140429 100-01295...
  • Page 21: Glass Frame Removal And Installation

    Hang the glass frame on the firebox. latch bracket. b) While holding in place, attach the upper latches (follow the instructions to the right in reverse). c) Lift the glass frame slightly and attach the lower latches. © Travis Industries 4140429 100-01295...
  • Page 22: Glass Frame Removal And Installation (Continued)

    You will need to push slightly to get the latch to insert. Glass Once fully inserted, turn the latch until it is is level. © Travis Industries 4140429 100-01295...
  • Page 23: Steps For Finalizing The Installation

    Synchronize the transmitter to the IFC (see page 26). Install the burner and media (and firebacks if applicable). Replace the glass. Start the heater. Leak test all gas joints. Check the air shutter following the directions below. © Travis Industries 4140429 100-01295...
  • Page 24: Air Shutter Adjustment

    The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer for a remedy. 12. Give this manual to the home owner for future reference and fully explain operation of this heater. © Travis Industries 4140429 100-01295...
  • Page 25: Before You Begin

    Turn off the main gas supply to the appliance during appliance installation or maintenance. During appliance installation or maintenance or in case of remote control malfunction turn off the main gas supply. © Travis Industries 4140429 100-01295...
  • Page 26: Remote Set-Up

    PRG (Program) button for 10 seconds. The pilot will start to spark repeatedly, signifying all system memory has been cleared. The system will return to its original configuration: a remote will need to be synchronized; and, the system will operate under continuous pilot mode. © Travis Industries 4140429 100-01295...
  • Page 27: Location Of Controls

    If you wish to adjust the mode settings use the transmitter mode button to adjust the settings (see “Mode Controls” on page 31). The thermostat and burner on/off operating functions will not work on the transmitter. © Travis Industries 4140429 100-01295...
  • Page 28: Starting The Fireplace For The First Time

    IPI/CPI. NOTE: This icon appears when the appliance is in CPI mode. Press the "UP" button Press the "DOWN" button to activate CPI mode. to activate IPI mode. Figure 4 © Travis Industries 4140429 100-01295...
  • Page 29: Remote Operation

    IFC. When you change thermostat target settings the IFC will not beep. NOTE: When the batteries start to get low, the IFC will beep intermittently. When the batteries are nearly depleted, the IFC will no longer beep. See “IFC Batteries” on page 33). © Travis Industries 4140429 100-01295...
  • Page 30: Manual On-Off / Smart Thermostat / Standard Thermostat

    Use the up or appear here. down buttons to adjust the target temperature. Figure 9 NOTE: If the transmitter batteries go dead while in thermostat setting (standard or smart), the appliance will shut off after approximately 24 hours. © Travis Industries 4140429 100-01295...
  • Page 31: Mode Controls (Flame, Blower, Light, Comfort Control)

    When in Manual Mode the blower will remain on, even if the burner is turned off and the heater cools. Either manually turn the blower off, or turn off the heater by pressing the On/Off button. © Travis Industries 4140429...
  • Page 32: Mode Controls - Continued

    (2 settings). darkened. Figure 14 Display Fahrenheit or Celsius  With the system in the “OFF” position, press both the MODE and THERMOSTAT buttons simultaneously to toggle between Fahrenheit (F) and Celsius (C). Figure 15 © Travis Industries 4140429 100-01295...
  • Page 33: Low Battery Indicator

    Figure 17 Power Outages The remote will work if household current (AC power) is disconnected. The batteries inside the battery box will continue to power the heater but the accent light and blower will not operate. © Travis Industries 4140429 100-01295...
  • Page 34: Child-Proof Feature

    This appliance has several areas that reach high temperatures. Dust or other particles on these areas may burn and create an odor. This is normal during start-up. You may notice the smell is more acute if the appliance was left idle for a long period. © Travis Industries 4140429 100-01295...
  • Page 35: Maintaining Your Heater's Appearance

    35 Watt 120 Volt T4 Halogen Bulb (G6.35 Base) Lower Accent Light The lower accent light is located at the back of the firebox behind the light deflector, as shown below. It can be removed by pulling it out. © Travis Industries 4140429 100-01295...
  • Page 36: Yearly Service Procedure

    Monitor blower operation. Remove any debris or vegetation near the vent termination. Contact your dealer if any sooting or deterioration is found near the vent termination. Venting system should be examined by a qualified agency. © Travis Industries 4140429 100-01295...
  • Page 37: Troubleshooting Table

    The bulb may be burned out......... See “Accent Light Replacement” on page Accent Light Does The accent light fuse may be blown...... Not Work Replace the fuse. See fuse location below. Location of Fuses Fan Lights © Travis Industries 4140429 100-01295...
  • Page 38: Wiring Diagram

    On/Off) Replacement Parts List Caution: Use only Travis Industries replacement parts. Do not use substitute materials. Warning: Do not operate appliance with the glass front removed, cracked, or broken. Replacement of the glass should be done by a licensed or qualified service person.
  • Page 39: Safety Label

    Safety Label Safety Label The safety (listing) label is attached to the operating tag (chained to the heater near the gas control valve). A copy is shown below © Travis Industries 4140429 100-01295...
  • Page 40: Burner Assembly

    2. Travis Industries has the option of either repairing or replacing the defective component. 3. If your dealer is unable to repair your appliance’s defect, he may process a warranty claim through TRAVIS INDUSTRIES, INC., including the name of the dealership where you purchased the appliance, a copy of your receipt showing the date of the appliance’s purchase, and the serial number on your appliance.
  • Page 41: Lp Conversion Instructions

    This control has been converted for use with gas_____.” Convert the appliance prior to installing the gas line to ensure proper gas use. 1. Access the firebox. 2. Remove the manifold cover to access the burner orifices (see below). © Travis Industries 4140429 100-01295...
  • Page 42 Front Burner Orifice Thread Sealant 15/16" 24mm 1/2" Wrench Orifice ID ORIFICE SIZE (ID) Natural Gas LP (Propane) Front Burner Orifice #50 DMS #58 DMS Rear Burner Orifice #47 DMS #56 DMS 4. Replace the manifold cover © Travis Industries 4140429 100-01295...
  • Page 43 25 Lb-inches. Leak-test this area after installing to verify proper installation. Re-attach the wiring. Restore the appliance to the correct configuration. Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve. © Travis Industries 4140429 100-01295...
  • Page 44 Troubleshooting Table ........37 Installation Options ..........6 Vent Requirements .......... 14 Installation Warnings .......... 7 Wiring Diagram ..........38 Items Packed with the Face ....... 8 Yearly Service Procedure ........ 36 Leveling Bolts ........... 11 © Travis Industries 4140429 100-01295...

Table of Contents