STORAGE & MAINTENANCE
PUMP MAINTENANCE:
The pump oil must be changed after the first 25 hours of operation. Once the initial
oil change has been completed, it is recommended the oil be changed every 3
months or 250 hour intervals. If oil appears dirty or milky, changes may be required
at a greater frequency. Use SAE 30W Non-Detergent oil and fill only to the center
of the oil sight glass. DO NOT OVERFILL!
NOZZLE MAINTENANCE:
Water flow through the spray nozzle will erode the orifice, making it larger, resulting
in a pressure loss. Nozzles should be replaced whenever pressure is less than
85% of the maximulm. The frequency of replacement will depend upon such
variables as mineral content in the water and number of hours the nozzle is used.