Operating Instructions; Priming The Pump; Start-Up - Nilfisk-Advance SelectSpray 1500E 56011781 Instructions For Use Manual

Pressure washer
Table of Contents

Advertisement

Available languages

Available languages

WARNING
RISK OF INJECTION CAUSING
SEVERE INJURY!
KEEP CLEAR OF NOZZLE! NEVER
PLACE HAND OR FINGERS IN
FRONT OF NOZZLE!
DO NOT DIRECT DISCHARGE
STREAM AT PEOPLE OR PETS!
BE CERTAIN THE ADJUSTABLE
NOZZLE ASSY. IS SECURELY
CONNECTED TO THE WAND TO
PREVENT AN ACCIDENTAL
DISCHARGE!
CAUTION
RISK OF DAMAGE.
DO
NOT
ALLOW
PATTERN TO REMAIN ON A FIXED
AREA FOR AN EXTENDED PERIOD
OF TIME. POSSIBLE DAMAGE
MAY OCCUR TO THE AREA.
14

PRIMING THE PUMP:

1. It is essential to prime the pump on initial start-up and each time the water
supply is disconnected from the unit after initial use.
2. Lay the high pressure hose out to remove any loops. Water flow will constrict
the hose, creating tight loops if the hose is not straight.
3. Securely connect the gun assembly to the high pressure hose.
NOTE: The nozzle assembly should NOT be connected to the gun assembly at
this time. (See Nozzle Connection" pg. 11)
4. With the trigger gun locked in the "OFF" position, turn the water supply
completely on. Pointing the gun in a safe direction, unlock the trigger gun and
squeeze the trigger.
5. Low pressure water will begin flowing from the hose/gun assembly. This allows
the unit to prime and purge any air from the system. The unit is primed when
water flow is uninterrupted by air.
6. Once the unit is primed, release the trigger and lock the gun in the "OFF"
position. Securely connect the nozzle assy. (See "Nozzle Connection"
pg. 11)

START-UP:

1. Refer to the "Safety Precautions" pgs. 4-7 before starting the unit.
2. Locate the Safety Decals on your unit and heed their warnings. (2,6,7,8,9)
3. With the gun locked in the "OFF" position, point the trigger gun away from
yourself or anyone else. Ensure water supply is turned completely on.
4. Disengage the safety lock-off on the gun and squeeze the trigger. Low
pressure water will begin flowing from the nozzle. Before starting the unit, brace
yourself as the gun will kick-back from the high pressure created by the pump
once the unit has started.
5. Move the On/Off Switch to the "ON" position. This switch includes a circuit
breaker for protection of the motor. In case of excess load, the circuit breaker
will automatically move the switch to the "OFF" position. To restart, move the
On/Off Switch to the "ON" position again.
6. Once the unit is turned on, perform the following procedures with the gun open:
a. Inspect for system water leaks and oil leaks.
If an oil leak is found, TURN UNIT OFF IMMEDIATELY!
Be sure that all damaged parts are replaced and that the
mechanical problems are corrected prior to operation of the unit.
If you require service, contact Nilfisk-Advance Customer Service.
b. Inspect high pressure hose for kinking cuts and leaks.
If a cut or leak is found, DO NOT TOUCH HOSE AT CUT OR
LEAK!!! TURN UNIT OFF IMMEDIATELY!
SPRAY
Replace hose before re-starting the unit. See "Miscellaneous
Safety Precautions #6, pg. 6. Be sure that all damaged parts are
replaced and that the mechanical problems are corrected prior to
operation of the unit. If you require service, contact Nilfisk-Advance Service.
c. Inspect electrical cord for cuts.
If a cut is found, DO NOT TOUCH OR USE ELECTRICAL CORD!
Replace cord before starting the unit.
7. Trigger the gun several times and try adjusting the spray pattern. Be certain
to LOCK the trigger gun in the "OFF" position whenever moving the adjustable
nozzle. NEVER look directly into the nozzle! High pressure water creates a
risk of severe injury!
8. Because your pressure washer delivers a high pressure spray and a variety
of spray patterns, there are many cleaning jobs that can be done without the
use of detergents. If a cleaning agent is required, see "Cleaning With
Detergents" pg. 15 for the correct procedures.

OPERATING INSTRUCTIONS

Nilfisk-Advance Select Spray 1500E Operator's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Selectspray 1500e56011781

Table of Contents