MPP Solar PIP-MS 1-5KVA User Manual page 22

Inverter / charger (800w-4kw)
Table of Contents

Advertisement

27
Floating charging voltage
29
Low DC cut-off voltage
Solar power balance:
When enabled, solar input
power will be automatically
31
adjusted according to
connected load power.
(Only available for
4KVA/5KVA model)
If self-defined is selected in program 5, this program can be
set up. Setting range is from 24.0V to 29.2V for 24V model and
48.0V to 58.4V for 48V model. Increment of each click is 0.1V.
24V model default to 27.0V
48V model default setting: 54.0V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 24.0V to 29.2V for 24V model,
48.0V to 58.4V for 48V model. Increment of each click is 0.1V.
24V model default setting: 21.0V
48V model default setting: 42.0V
If self-defined is selected in program 5, this program can be
set up. Setting range is from 20.0V to 24.0V for 24V model,
40.0V to 48.0V for 48V model. Increment of each click is 0.1V.
Low DC cut-off voltage will be fixed to setting value no matter
what percentage of load is connected.
Solar power balance
enable (Default):
Solar power balance
disable:
20
If selected, solar input power will
be automatically adjusted
according to the following formula:
Max. input solar power = Max.
battery charging power +
Connected load power.
If selected, the solar input power
will be the same to max. battery
charging power no matter how
much loads are connected. The
max. battery charging power will
be based on the setting current in
program 02.
(Max. solar power = Max. battery
charging power)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents