Preparing The Opening; Minimum Clearances; Overall Cooktop Dimensions; Vertical Clearances - GE Monogram ZEU30R Installation Instructions Manual

30" electric radiant cooktop
Hide thumbs Also See for Monogram ZEU30R:
Table of Contents

Advertisement

Minimum
The following MINIMUM clearance
Clearances
dimensions must be maintained.
Overall
Cooktop
Dimensions
3 1/4"
Vertical
Five inches (5") minimum vertical clearance between the
Clearance
cooktop bottom and any combustible surfaces.
Cutout
Dimensions
To insure accuracy, it is best to make a
template when cutting the opening in the
of the
counter. Make sure there is clearance
Countertop
inside the cabinet before cutting the
countertop.
Wall
Make sure the wall coverings, counter top and
cabinets around the cooktop can withstand heat
Coverings,
(up to 200°F) generated by cooktop.
Counter
Top,
& Cabinets
4
29 3/4"
21 5/8"
C L C L
20 7/8"
19 1/4"

Preparing the Opening

Electronic Radiant Cooktop
13" MAX. Depth
of unprotected
overhead cabinets
3 1/4"
20 7/8"
28"
CURVED GLASS
1 3/4"
Between Cooktop
rear edge and the
wall behind the cooktop
30" MIN.
clearance from
countertop to
unprotected
overhead surface
2" MIN.
clearance from
cutout to side
wall on the left
of the unit
5"Min.
Vertical Clearance
28 1/2"
length
of cut
2 1/2" from
front edge of cooktop
and front edge of countertop
Wall covering,
cabinets, and
countertop
must withstand
heat up to
200F.
1 1/2" MIN.
clearance from
cutout to side
wall on the right
of the unit
18" MIN.
height from
countertop to
nearest cabinet on
either side of unit
6 1/4"
5 1/2"
19 5/8" width of cut