1
When making the wire connections, use the entire length of conduit provided. The conduit must not be
shortened.
Step
2
With the cooktop in place open the front of the cabinet door.
Step
Insert the wires from the conduit through the opening
3
of the junction box.
Step
4
Connect the red and black leads from the
cooktop conduit to the corresponding leads in
Step
the junction box.
5
Once the connections are made, secure wires
together using wire nuts.
Step
The bare ground wire in the conduit is connected to the cooktop frame. When connecting to a 3 conductor
branch circuit, if local codes permit, connect the bare ground connector lead of the cooktop to the branch
circuit neutral (gray or white in color).
SPECIAL GROUNDING INSTRUCTIONS
• When connecting to a 4-conductor branch circuit
• When local codes do not permit grounding through neutral
• When installing cooktop in a mobile home
Attach the appliance grounding lead (bare copper) to the residence grounding conductor (green or bare
copper) in accordance with local codes.
IMPORTANT:If the cooktop is being installed into a blind
counter (one with no cabinet opening below), wire
!
connections must be made before putting the cooktop into
the cutout opening.

Electrical Connections

Electronic Radiant Cooktop
Red
Ground
Ground
wire
location
Red
Black
Ground
Strain
Relief
Clamp
Black
Red
Black
Strain
Relief
Clamp
7