AIR CONDITIONER FEATURES
TO SELECT THE OPERATING MODE:
To choose operating mode, press
each press of the button, the mode will cycle through
the following sequence: Auto, Cool, Dry and Fan. The
indicator light next to each corresponding model will
illuminate.
AUTO mode:
· When the air conditioner is set in AUTO mode, unit
will automatically select cooling or fan operation,
depending on set and ambient temperature.
· Unit engages COOL mode when ambient temperature
is 4°F above set temperature. When ambient
temperature falls 2°F below set temperature, unit will
switch to Fan.
· Fan speed cannot be adjusted in AUTO mode.
COOL mode:
· Unit begins cooling when ambient temperature is 2°F
above set temperature. When set temperature has
been reached, cooling stops and unit switches to
Fan mode.
DRY mode:
· In this mode, the unit will generally operate in the form
of a dehumidifier. Since the conditioned space is
closed or sealed area, some degree of cooling will
continue.
FAN mode:
· Use this function when cooling is not desired, such as
for air circulation or to exhaust stale air. Best to open
windows when operating in Fan mode but remember
to close windows in Cool mode for maximum cooling
efficiency.
· Fan speed can be selected.
· The display will show actual room temperature.
· Temperature cannot be set or adjusted.
SLEEP FEATURE:
Press
Sleep button to initiate the sleep mode. The
unit will operate at set temperature for 30 minutes.
After 30 minutes, unit will increase temperature by 2°F.
After another 30 minutes, unit will again increase
temperature by 2°F. This new temperature will be
maintained for 6 hours before unit returns to originally
set temperature. This ends the Sleep mode and unit
will continue to operate as originally programmed. The
Sleep Mode can be cancelled at any time during
operation by pressing the Sleep button again.
Mode button. With
Press
This feature can be selected when unit is in COOL,
DRY or AUTO mode. When the set temperature
has been reached and compressor shuts off, fan
will continue to run for another 3 minutes, then
cycles on for 2 minutes at 10-minute intervals until
the room temperature is above the set temperature,
at which point the compressor turns back on and
cooling resumes.
· Press the
· Use the Left/Right arrow buttons to program. Each
· Unit will register timer setting after 5 seconds. If
· Turning the unit on or off or adjusting the timer to
DISPLAY:
· COOL mode: shows set temperature in "°C" or
· FAN mode: shows ambient temperature.
ERROR CODES:
· "AS" = room temperature sensor error. Unplug the
· "•" = Evaporator temperature sensor error. Unplug
9
CHECK FILTER FEATURE:
Press
Check filter button to initiate this feature.
This feature is a reminder to clean the Air Filter for
more efficient operation. The LED light will
illuminate after 250 hours of operation. Once the
filter has been cleaned, press the Check Filter
button to reset.
ENERGY SAVER FEATURE:
Energy Saver button to initiate this feature.
TIMER: AUTO START/STOP FEATURE:
TIMER button to program Auto-On or
Auto-Off. The corresponding indicator light will
illuminate.
press is in increment of 0.5 hours up to 10 hours,
then in increments of 1 hour up to 24 hours. The
control will count down the remaining time.
unit is on, display will revert back to previous
temperature setting or room temperature. If unit is
off, there will be no display.
0.0 will cancel the timer program.
DISPLAY:
Temp
Temp
Timer
Timer
"°F" and Auto-timer settings.
unit, wait 3 minutes and plug it back in. If error
persists, call for service.
NOTE: In FAN mode, it will display "LO" or "HI".
unit, wait 3 minutes and plug it back in. If error
persists, call for service.