Arming Partitions Via The Keypad; Disarming Partitions Via The Keypad - Pyronix PCX 256 User Manual

Hide thumbs Also See for PCX 256:
Table of Contents

Advertisement

2.1.3 Arming Partitions Via The Keypad

If the system is set up as a partition system, the master manager can assign different codes to
individual partitions. Please see Change Codes on page: 22.
1. Enter your user code (default 1234) or present your card
2. Before you can arm the system, any active faults will be displayed (see above), press the
key.
3. The system will allow you to arm the required arm mode.
4. Use the numeric and the ¤,¦,§,© keys to select the partition(s) you wish to arm and press
the
key. The system will start to arm. Once the system has armed, a beep will be heard and
the system is armed.
NOTE: The system will only arm depending on what 'Exit Mode' is programmed. This would
have been selected by your engineer. For example:
If Timed is selected the system will arm after the exit time has expired.
If Final Door is selected, the system will only arm after the entry/exit door has been opened/closed.
If PTS (Push To Set) is selected, the system will only arm after the Push To Set button has been
pushed.

2.1.4 Disarming Partitions Via The Keypad

To disarm any partition on the system:
1. If you have only one partition assigned to the card/code, then the partition will be disarmed
automatically (this coincides with the 'Flexi-Arm' option – please see page 24). If you have
multiple partitions assigned to a user, then the following will be displayed when you enter your
code or present your card (In this example partitions A and B were armed initially)
RINS867-2
Active Faults
Battery Fault100
Tag
,/+.
ABC
DEF
GHI
JKL
MNO
PQRS
TUV
WXYZ
SPACE
P C X 2 5 6 U S E R M A N U A L
A
B
C
D
Page: 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents