P C X 2 5 6 U S E R M A N U A L
FAIL
failed
Battery being disconnected
BATTERY
CRITICAL
Mains supply failed
MAINS FAIL
xxx
Fuse identified failed,
OR Output protected by
fuse
current
FUSE x
FAULT
Power supply volts low
LOW VOLTS
xxx
Page: 34
drawing
excessive
Battery uncharged or capacity below specification
may need replacing.
Protects battery from deep discharge damage
during extended mains failure.
Note: System is now powered down!
System detects mains frequency out of
specification, as well as voltage. Note: 'AC FAIL'
timer operative
x identifies fuse affected:
Fuse 1 = +12v at AUX1+ terminals
Fuse 2 = +12v at K+
Fuse 3 = +12v at AUX3+ terminals
Fuse 4 = BATTERY 0v
Fuse 5 = +12v at AUX4+terminals
Note: Fuse 6 failure will cause SAB Tamper
fault.
Battery volts below normal 'battery fault' level
during mains failure
RINS867-2