If a device on the PCX system is not installed correctly or has lost its communication with the
panel, "DEVICE FAIL" will be shown on the LCD keypad followed by a 3-figure device code. The
first digit identifies each type of device:
The digits after refer to that devices address, for example:
DEVICE FAIL 401 = means that the Remote Input Expander addressed as "01" has a problem.
Fault
Description
MODEM
End Station unable to
FAULT
communicate with Digi
Modem
DIGI FAIL
Call to ARC from Digi
COMM
Modem DigiModem has
failed.
Note: This is a
communication problem,
which is rarely caused by
an equipment fault.
PHC TEST
Unable
FAIL
with
Computer.
Note: This would also
result if the telephone line
had premium rate calls
blocked.
LINE FAULT
PSTN Line Fault signalled
100
by Digi Modem.
ATE LINE
PSTN Line Fault signalled
FAULT
by device using STU/ATE
pins on End Station.
ATE FAIL
Call to ARC from device
COMM
using End Station STU/ATE
Page: 32
A P P E N D I X A :
D e v i c e C o d e s
1 = E n d S t a t i o n
2 = K e y p a d
3 = T a g R e a d e r / D o o r S t a t i o n / R I X 2
4 = R e m o t e I n p u t E x p a n d e r
5 = R e m o t e O u t p u t E x p a n d e r
F a u l t I n d i c a t i o n s
COMMUNICATION FAULTS
Solution
If modem not present, ensure that "Disable Digi"
option is set to 'YES' and "DOWNLOAD MODE" is
set to 'NONE' or 'RS232'.
If present, but not detected, check Digi Modem is
inserted correctly and complete initialisation by
pressing End Station 'RESET' button for 2
seconds.
Check ALL call details are programmed correctly.
Ensure signalling format is correctly set for ARC
receiver.
If only one call number programmed, ensure
"STOP ON SUCCESS" = 'YES' and "TRY SAME"
is selected – NOT "TRY NEXT".
to
communicate
Ensure Digi is enabled, and at least one SMS call
Pyronix
Host
is correctly programmed.
Check that ordinary phone on same line connects
to PHC and modem tones heard - if not, problem is
PSTN – NOT equipment.
De-program SMS content types for each call, exit
Engineer menu, press RESTART button, and retry
PHC test from Manager menu.
Only operative if "DOWNLOAD BY MODEM"
selected OR "DISABLE DIGI/SMS" is set to 'NO'
Note: 'Line Fault' timer operative.
Only operative if Site Option "DIGIREPLY" is set to
'STU' or 'Digicom.'
Note: 'Line Fault' timer operative
Only operative if Site Option "DIGIREPLY" is set to
'Digicom.'