Large Lava Rock Placement; Flame Adjustment (Rn/Rp Models); Temperature Adjustment (Tn/Tp Models); Flame Characteristics - Majestic Vemont Castings RHE25 Installation Instructions & Homeowner's Manual

Natural vent insert
Table of Contents

Advertisement

Vermont Castings, Majestic Products RHE Natural Vent Insert
JR5
JR2
Burner Lava Rock
LG279
Placement
Fig. 17 RHE25 log and lava rock placement.
KR5
KR2
Fig. 18 RHE32 log and lava rock placement.
SR5
LG280
SR2
RHEDV32
log1/03
Burner Lava Rock
Placement
Fig. 19 RHE42 log and lava rock placement.

Large Lava Rock Placement

The large lava rock provided with this fireplace must be
LG281
placed on the firebox base on either side of the burner
RHEDV42 logs
assembly.
1/03
Under no circumstances should these
lava rock be placed on top of the burner
assembly.
12
JR6
JR4
KR1
LG279
KR6
RHEDV 25 logs
KR4
1/03
KR3
KR1
Burner Lava Rock
LG280
Placement
SR6
SR4

Flame Adjustment (RN/RP Models)

For fireplaces equipped with HI/LO valve, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control.
JR3
(Figs. 20 & 21)
Turn
counterclockwise
to decrease
flame height
Fig. 20 Flame adjustment knob for Honeywell Valve.
Turn
counterclockwise
to increase
flame height
Fig. 21 Flame adjustment knob for SIT Valve.

Temperature Adjustment (TN/TP Models)

The HI/LO reference on the control knob (Fig. 22) is
to indicate a higher or lower temperature setting. This
setting controls the heat by reducing then shutting off
the flame after the desired temperature is reached.
Position the control knob where it effectively maintains
a comfortable room temperature.
SR3
SR1
LG281
Fig. 22 Temperature adjustment knob for TN/TP models.
It is important to periodically perform a visual check
of the pilot and the burner flames. Compare them to
Figure 23 and Figure 24 or 25. If any of the flames
appear abnormal, call a service person.
Turn clockwise
Turn clockwise
HV102
Honeywell hi/lo knob
4/5/99 djt
FP390
FLAME ADJUSTMENT KNOB
11/21/96

Flame Characteristics

FP1288
TN/TP gas control knob
2/03
to increase
flame height
to decrease
flame height
10000836