Fan Kit; Fan Removal Instructions - Majestic Vemont Castings RHE25 Installation Instructions & Homeowner's Manual

Natural vent insert
Table of Contents

Advertisement

Vermont Castings, Majestic Products RHE Natural Vent Insert
Operation of this fireplace when not
connected to a properly installed and
maintained venting system or tampering
with the vent safety shutoff system can
result in carbon monoxide (CO) poisoning
and possibly death.

Fan Kit

115 Volt, 60 Hz. 56W
The fan kit includes the following: fan, temperature
sensor, speed control and a 6 ft. cord. The following
explains how to start and set the fan for automatic
operation.
1. Plug in the electrical cord.
2. Start gas fire - see lighting procedures.
3. Turn on fan speed control.
4. Wait until the unit has warmed up sufficiently to
activate the temperature sensor.
5. Once fan starts, adjust speed control to desired fan
speed. The fan will now automatically come on every
time the fireplace is in operation. Should the fan not
be needed simply turn off the speed control.
The appliance, when installed must be
electrically connected and grounded in
accordance with local codes or, in the ab-
sence of local codes, with the current CSA
C22.1 Canadian Electrical Code.
For U.S.A. installations, follow local codes
and the national electrical code, ANSI/NFPA
No. 70.
Should this fan require servicing, the
power supply must be disconnected. For
rewiring of any replacement components
refer to Figures 13 & 14.

Fan Removal Instructions

1. Turn off gas and electricity.
2. Remove the front glass.
3. Remove the logs.
4. Remove burner assembly and rear log support plate.
5. Remove the fan mounting nuts (2). (Fig. 13)
6. Slip off the electrical connector at the motor.
7. Lift out the fan.
8. To reinstall, reverse procedure.
10
Thermal Sensor is
attached to burner
base
Stud
Fan Speed Control/Junction Box
Fig. 13 Fan location.
Temperature Sensor
Speed
Control
Black
White
Ground
Fig. 14 Wiring diagram RN/RP.
FP394
WIRING DIAGRAM
11/20/96
Stud
Fan is installed
at the back of
the air intake
box
Valve
FP1252
Fan
FP1252
FK24 install
1/03
FP394
10000836

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vemont castings rhe32Vemont castings rhe42