MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR DUAL TIMER OR PHASE 5 WITHOUT HEAT FAULT
This dryer was manufactured with a manual reset basket (tumbler)/lint chamber hi-limit thermostat. If the
manual reset thermostat is open prior to the start of the drying cycle, or during the cycle, the dryer will not
recognize the open state of the hi-limit thermostat and will start or continue through the drying cycle with no heat.
Manual reset hi-limit must be reset manually.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper heating unit
operation.
The location of the manual reset hi-limit is in the lint chamber area.
WARNING: Discontinue power to the dryer before attempting to reset hi-limit.
I M P O R T A N T

(ELECTRIC or STEAM MODELS ONLY)

IMPORTANT
This dryer is equipped with a lint
chamber hi-limit thermostat which must
be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.