1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Tripped burner hi-limit circuit.
3. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
4. Failed heat selector switch.
ELECTRIC MODELS ONLY
1. Fault in sail switch circuit...
a. Sail switch is out of adjustment and/or failed.
b. Sail switch is not closing or fluttering...
1) Check blower (impellor/fan) motor and rotation direction.
2) Restriction in location exhaust system.
2. Failed oven hi-limit circuit.
3. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
4. Failed oven contactor/relay.
5. Failed heat selector switch.
STEAM MODELS ONLY
1. Steam damper binding and/or stuck.
2. Tripped lint compartment manual reset (225º F [107º C]) safety thermostat circuit.
3. Failed heat selector switch.
G. Heat unit is not operating for only one (1) temperature selection...
1. Failed thermostat corresponding to selection made.
2. Failed heat selector switch.
H. Dryer operates but is taking too long to dry load...
1. Heating unit cycling on hi-limit thermostat (for electric models only).