Dual Timer Models - Continental Girbau CG75-85 Installation Manual

Gas dsi/electric/steam
Hide thumbs Also See for CG75-85:
Table of Contents

Advertisement

2. Basket (tumbler) is out of proper alignment...
a. Check both vertical and lateral alignment.
b. Check gap between front panel and basket (tumbler) front, setscrews may have come loose and basket
(tumbler) walked forward or backwards.
3. Loose basket (tumbler) tie rod.
4. Failed basket (tumbler) support.
T.
Excessive noise and/or vibration...
1. Dryer is not leveled properly.
2. Impellor (fan/blower) is out of balance...
a. Excessive lint build up on impellor (fan/blower).
b. Failed impellor (fan/blower).
3. Loose basket (tumbler) tie rod.
4. Basket (tumbler) is out of adjustment or adjustment bolts (hardware) are loose.
5. Failed basket (tumbler) support.
6. Loose motor mount.
7. Failed idler and/or basket (tumbler) bearings.
8. V-belt(s) either too tight or too loose.
U. Main burners are burning with a yellow flame (for gas models only)...
1. Burner air shutters are out of adjustment.
2. Insufficient make-up air.
3. Dust and/or lint in burner.
4. Insufficient gas pressure.
A. Dryer will not start, both drive and blower motors are not operating (indicator light is off)...
1. Dryer control circuit fuse is blown.

DUAL TIMER MODELS

50

Advertisement

Table of Contents
loading

Table of Contents